Related Experiment Video
Updated: May 3, 2026

Façade-Level Monitoring of CO2 Variability under Urban Heat Island Conditions using Low-Cost Sensor Data Loggers
Published on: December 12, 2025
Window typology as a determinant of indoor air quality in naturally ventilated tropical African offices
Amaka-Anolue Martha Basil1, Chiamaka Christiana Okwuosa1, Ejike Kingsley Anih1
1Department of Architecture, Faculty of Environmental Studies, University of Nigeria, Nsukka, Nigeria.
Abstract:
Indoor air quality (IAQ) is a critical determinant of health and productivity in tropical African office environments where natural ventilation is the primary ventilation strategy, yet the influence of architectural factors such as window typology remains understudied. This study examined how casement, projecting, and louvered window systems, along with associated architectural features, affect measured IAQ in naturally ventilated government offices in Enugu, Nigeria. Using a cross-sectional observational design, the study assessed 54 offices and measured carbon monoxide (CO), carbon dioxide (CO2), formaldehyde (HCHO), total volatile organic compounds (TVOC), particulate matter (PM2.5), temperature, and relative humidity (RH). Data were analyzed with ANOVA and multivariate linear regression to isolate the effects of window typology while controlling for structural covariates like headroom, floor area, occupancy, etc. Significant IAQ differences were observed across window types, and the multivariate models identified window typology as a robust predictor for HCHO, RH and PM2.5. Casement windows consistently produced the most favourable IAQ profile, yielding the lowest adjusted pollutant concentrations. Compared to casement windows, projecting windows were associated with higher RH (B = 3.61%, p = 0.003), higher PM2.5 (B = 3.17 µg/m3, p = 0.005), and higher HCHO (B = 0.012 mg/m3, p = 0.019). Similarly, combined louvered + projecting windows were associated with significantly higher RH (B = 1.64%, p = 0.045), PM2.5 (B = 2.19 µg/m3, p = 0.005), and HCHO (B = 0.008 mg/m3, p = 0.021) than casement types. Adjusted PM2.5 was lowest in casement offices (3.83 µg/m3), while projecting-window offices recorded the highest adjusted RH (70.56%). Although unadjusted findings suggested window-related differences in carbon dioxide, the final regression indicated that the number of windows (B = -9.24, p = 0.041), rather than typology, was the stronger predictor. Overall, the study demonstrates that window geometry is an important determinant of pollutant dilution and moisture control in naturally ventilated tropical office buildings, and that performance-based window selection represents a low-cost passive strategy capable of improving indoor environmental quality and supporting energy efficiency.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Design Example: Sustainability in Concrete Building
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground...
Types of Building Separation Joints
Volume-change joints address the effects of expansion and contraction due to temperature and moisture variations. They are strategically placed at discontinuities in a building's mass where cracking is most likely and are spaced about 150 to 200...