Flexibility-aware framework for efficient planner-initiated siting of data center
Dongjoo Kim1, Lin Dong1, Le Xie2
1Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX, USA.
Abstract:
Explosive growth in energy-intensive AI data centers is outstripping the pace of power grid interconnection and transmission expansion. While operational flexibility has been proposed to mitigate this stress, existing processes are often reactive and evaluate projects only after they enter a multi-year interconnection queue. To address this, we introduce a planner-initiated siting framework that integrates (i) reliability-gated screening, (ii) system-wide market-impact assessment under standardized flexibility envelopes (firm, pause, and shift), and (iii) entropy-weighted multi-criteria scoring to produce ranked, pre-certified catalogues of interconnection-ready locations. Applied to a synthetic 2000-bus Texas power system, the framework demonstrates that operational flexibility expands the siting frontier by 9-17% at 1 GW and 19-21% at 2 GW compared to firm operation. Median all-hour average prices remain essentially unchanged ($24.32/MWh for the 2 GW cases), and the shift envelope attenuates peak-hour price dispersion by approximately 3.4% with minimal side effects during off-peak hours. Utilizing pre-certified envelopes to bypass major transmission reinforcements, this workflow enables first energization in 12-18 months-a conservative reduction of 3.5-4 years versus the conventional 5-8 year project-led process. This technology-agnostic framework provides a proactive decision-making tool for system operators and regulators to fast-track large flexible loads while preserving grid reliability and market stability.
Related Concept Videos
Maximum Power Flow and Line Loadability
Fast Decoupled and DC Powerflow
Distributed Loads
For example, consider a bookshelf filled with books stacked vertically adjacent to each other. The weight of the books is evenly distributed over the length of the shelf. As a result, the pressure at different locations on the surface of the...
Design Example: Analyzing Capacity Contours for Flood Risk Assessment
Distributed Loads: Problem Solving
Design Example: Sustainability in Concrete Building
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground cistern.