Fault-tolerance amplification in line graphs: a framework for resilient PMU placement in power networks
Lakshmi Girish1, Ahmad Asiri2, K Somasundaram3
1Department of Mathematics, Amrita School of Physical Sciences, Amrita Vishwa Vidyapeetham, Kochi, India.
None:
The placement of Phasor Measurement Units (PMUs) is fundamental to achieving reliable observability in electric power networks, especially when measurements are subject to hardware failures or communication outages. Motivated by the need to understand how robustness behaves under different network representations, this paper studies the k-fault tolerant power domination number [Formula: see text] under the line graph transformation L(G). In this paper, we establish a correspondence between power domination in a graph and the induced monitoring process in its line graph, thereby linking vertex-based and edge-based perspectives on network observability. Within this dual framework, we prove the Fault-Tolerance Amplification Theorem, which states that if [Formula: see text] is a k-fault tolerant power dominating set of G, then the induced set in L(G) is Q-fault tolerant, where [Formula: see text]and [Formula: see text] are the [Formula: see text] smallest degrees among the vertices of [Formula: see text]. And Q attains its upper bound when [Formula: see text] is an independent k-fault tolerant power dominating set of G. These results provide a topology-aware framework for resilient PMU placement, clarifying when degree-based fault-tolerance amplification is valid and highlighting structural conditions under which additional care is required. We have validated our results with IEEE bus systems.
Related Concept Videos
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Maximum Power Flow and Line Loadability
Fault Types
For line-to-line faults occurring between phases B and C, the...