Interpretable side-aware kinematic-sEMG gait-state representations relevant to adaptive neurorobotic assistance after
Rocco Salvatore Calabrò1, Andrea Calderone1, Alessio Baricich2,3
1IRCCS Centro Neurolesi Bonino Pulejo, Messina, Italy.
Background:
Adaptive lower-limb neurorobotics requires gaitd-state representations that preserve locomotor structure without reducing post-stroke walking to a single asymmetry score or opaque latent embedding. Because post-stroke gait is multimodal and side dependent, transparent side-aware representations may better support future adaptive-assistance design than modality-isolated summaries.
Methods:
This secondary analysis used a public multimodal gait dataset comprising 138 able-bodied adults and 50 adults with stroke. The analytic space was restricted to 11 waveform domains shared across public exports: four sagittal kinematic waveforms and seven repository-normalized surface electromyography waveforms, each represented by 1,001 time-normalized points. Stroke waveforms were organized into paretic, non-paretic, bilateral-mean, and side-difference views, with side difference defined as paretic minus non-paretic. Domain-view functional principal component analysis retained 90% cumulative variance, capped at three components per block; family-level reduction retained 90% variance, capped at eight components. Candidate Ward hierarchical and K-means solutions from two to five states were screened in kinematics-only, sEMG-only, fused, paretic-only, and erector-spinae-excluded spaces.
Results:
The retained fused side-aware solution organized the strict complete-case stroke cohort (n = 43) into three states: State 1 (n = 12), State 2 (n = 18), and State 3 (n = 13). The strongest fused two-state K-means comparator showed higher compactness and resampling stability than the retained three-state solution [silhouette 0.189; bootstrap adjusted Rand index (ARI) 0.876 versus silhouette 0.155; bootstrap ARI 0.633]. However, the three-state solution was retained as a representation-level choice because it avoided trivial micro-clusters, preserved explicit multimodal side-aware structure, and enabled clearer waveform-level interpretation. Sensitivity analyses showed identical assignments after erector-spinae exclusion (ARI = 1.000), partial concordance under robust scaling (ARI = 0.785), and material reassignment when the block cap was reduced to two components (ARI = 0.335). The strongest domain contributors were ankle angle (1.000), vastus lateralis sEMG (0.898), knee angle (0.866), gastrocnemius sEMG (0.851), and tibialis anterior sEMG (0.840).
Conclusion:
Public waveform exports supported an internally interpretable, side-aware multimodal representation of post-stroke gait relevant to neurorobotic state-representation design. This contribution remains exploratory and representational, not clinical, interventional, real-time, or controller-validating; for future studies, it should be interpreted as a hypothesis-generating framework.