A Speed-Dependent Assessment of E-Textile-Based Sensor Technology: Validity of the Prevayl Wearable Heart Rate
Louise C Burgess1, Matthew Armstrong1,2, Louise Beresford1
1School of Allied Health and Exercise Science, Bournemouth University, Poole BH12 5BB, UK.
Background:
The use of wearable sensors to measure and monitor heart rate has exponentially grown in recent years, representing an inexpensive, time-efficient, and non-invasive method to assess the status of cardiovascular fitness and the autonomic nervous system. Validating new devices against a criterion standard, such as electrocardiography (ECG), is essential to ensure their accuracy and reliability. This study examined the accuracy and validity of the Prevayl heart rate monitor against 3-lead ECG.
Methods:
Twenty-six healthy adults (15 female, mean age 32.0 ± 10.4 years) completed a 16-min, incremental running test on a treadmill. Heart rate data were recorded simultaneously throughout the test via ECG and the Prevayl wearable and compared retrospectively. Beat count error (%), mean heart rate absolute error (beats per minute (bpm)), and percentage error (bpm) were calculated. In addition, a Bland-Altman analysis and Pearson's correlation coefficient were conducted to assess agreement and correlation, respectively.
Results:
The Prevayl device demonstrated a median beat count agreement of 100.5% with ECG (range: 98.6-104.4%; Npart = 26). Strong correlations were observed between ECG and Prevayl for both raw beat count (r = 0.94, p < 0.01) and heart rate (beats per minute (bpm)) from ECG and the Prevayl algorithm (r = 0.96, p < 0.01). Across running speeds (0-12 kph), a strong correlation was found between raw beat count from ECG and Prevayl (r = 0.82-0.89, p < 0.01) and between bpm from ECG and Prevayl (r = 0.86-0.93, p < 0.01). Bland-Altman plots demonstrated negligible systematic bias.
Conclusions:
The Prevayl system provides valid measurements when compared to ECG during incremental running. This is demonstrated through strong correlations to ECG heart rate data at different speeds and with different analysis methods, supporting its use for monitoring cardiovascular responses during exercise.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Holter Monitor: 24-Hour Monitoring
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Special considerations while measuring pulse