Related Experiment Video
Updated: Jun 20, 2026
![An Automated Radiosynthesis of [68Ga]Ga-FAPI-46 for Routine Clinical Use](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F66708.jpg&w=3840&q=50)
An Automated Radiosynthesis of [68Ga]Ga-FAPI-46 for Routine Clinical Use
Published on: May 24, 2024
Automated and manual synthesis of [68Ga]Ga-DOTA-4AH29 intended for PET-imaging of FAP-expression
Marion Berdal1,2, Surasa Nagachinta3, Ximena Langsberg3
1Precirix NV/SA, Brussels, Belgium. marion.berdal@vub.be.
Background:
Fibroblast activation protein is a well-established target for tumour imaging, and single-domain antibodies (sdAb) offer favourable pharmacokinetic properties for PET applications. However, the translation of sdAb-based radiotracers into robust and clinically applicable manufacturing processes remains limited. Previously, preclinical protocol for the production of [68Ga]Ga-DOTA-4AH29 has been reported. In this study, this process was adapted for clinical use. Both a manual, kit-based approach and automated synthesis on two different platforms were developed. Process robustness was assessed through a stress study evaluating key parameters, and compatibility with two 68Ga generator systems was investigated.
Results:
Efficient radiolabelling was achieved at 50 °C for 10 min, with radiochemical conversion exceeding 90% and no need for purification. Both automated and manual processes showed consistent performance, with radiochemical purities of 99.5 ± 0.5% (n = 9) and 96.3 ± 1.5% (n = 8) as determined by iTLC and SE-HPLC respectively, with associated non-decay-corrected radiochemical yields of 78.3 ± 3.3% (n = 9) and 76.9 ± 2.1% (n = 8). The main source of activity loss was the radioactive decay of 68Ga.The process remained stable across a range of activities and buffer conditions. Comparable results were obtained with both 68Ga generator systems, with no observable impact on product quality. The final product was stable for at least 3 h at RT, with preserved binding capacity.
Conclusion:
A robust and reproducible manufacturing process for [68Ga]Ga-DOTA-4AH29 was established, supporting both automated and manual clinical production. This approach will facilitate broader access to sdAb-based PET imaging across clinical centres.
![Automated Preparation of [68Ga]Ga-3BP-3940 on a Synthesis Module for PET Imaging of the Tumor Microenvironment](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F68356.jpg&w=3840&q=50)
