Sustained Decrease in Oxygen Saturation in Human Fibular Fractures Monitored with Laser-Doppler and White-Light
Tokio Kawamura1,2,3, Selma Fensel-Merz1,4, Marcel Orth4
1Department of Experimental Musculoskeletal Medicine, Clinics and Institutes of Surgery, Saarland University, 66421 Homburg, Germany.
None:
Noninvasive light-based measurements have recently been suggested for monitoring fracture healing and for the development of smart implants. The aim of this study was to collect the first exploratory longitudinal in vivo data from human distal fibular fractures. In this prospective observational pilot study, blood flow, oxygen saturation, and relative hemoglobin were noninvasively measured by using combined laser Doppler and white-light spectroscopy at depths of 3 mm and 10 mm. In patients with fibular fractures, measurements were performed at 1-3 days, 2 weeks, 6 weeks, 3 months and 6 months after surgery. Patients with fibular nonunion and healthy control participants underwent a single measurement. Fourteen longitudinal fracture patients, a nonunion patient, and 42 controls were included. In the longitudinal fracture group, oxygen saturation at a depth of 10 mm significantly decreased from baseline to 2 weeks (p < 0.001) and remained at a low plateau significantly below healthy control levels throughout the 6-month period. Blood flow and relative hemoglobin levels did not longitudinally change but remained significantly elevated compared with controls (p < 0.001). A single nonunion case demonstrated a markedly low oxygen saturation value (8.3%) combined with increased blood flow. Fibular fractures treated with plate fixation exhibit a prolonged low-oxygen saturation plateau, in contrast to the rapid recovery observed in tibial shaft fractures, possibly due to differences in anatomy or healing mechanisms. The low oxygen saturation observed in the nonunion requires further investigation, as it may have prognostic potential.
More Related Videos
09:04Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
04:44Near-Infrared Spectroscopy During Reactive Hyperemia for the Assessment of Lower Limb Vascular Function
Published on: March 22, 2024
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.