Related Experiment Video
Updated: Jun 27, 2026

Manufacturing Simple and Inexpensive Soil Surface Temperature and Gravimetric Water Content Sensors
Published on: December 21, 2019
Static Calibration and Wiring-Configuration-Dependent Performance of NiCr-Based Thin-Film Thermocouples
Wenqian Yuan1, Zhongfeng Kang1
1School of Information Science and Engineering, Lanzhou University, Lanzhou 730000, China.
Abstract:
Thin-film thermocouples (TFTCs) offer conformal sensing junctions with minimal thermal mass, enabling rapid transient response and direct deposition on curved or moving components, which are difficult to achieve using conventional wire thermocouples in applications such as high-speed machining, electric powertrain thermal management, and fuel-cell monitoring. In practical deployment, the effective accuracy of a TFTC can also be affected by the measurement setup used for calibration and testing, particularly lead-wire material transitions, cold-junction compensation, and wiring-related thermoelectric offsets. This study presents a systematic static calibration and performance evaluation of NiCr-based TFTCs under standardised laboratory conditions, with repeated measurements across the 20-260 °C range using both copper leads and matched compensation wires. The thermoelectric output exhibits excellent linearity; temperature reconstruction against a traceable standard reference yields a maximum deviation of approximately 0.27 °C, with root-mean-square and relative errors within tight bounds. Short-term extended-range verification up to 1000 °C confirms detectable thermoelectric signal generation under the present test conditions. A calibration data packet framework containing the calibrated TFTC sample, wiring configuration, calibration coefficients, validity range, and a GUM-compliant uncertainty budget is proposed to support consistent interpretation of calibration results in future digital integration. The study therefore provides a structured calibration workflow and uncertainty-reporting basis for the tested flexible NiCr-based TFTC configurations, supporting further reliability assessment, material-level characterisation, and digital integration.
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...