Related Experiment Video
Updated: Jun 27, 2026

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples
Published on: June 9, 2016
Magnetic Composites for Advanced Characterization of Magnetic Field Sensors and Biosensors
Ekaterina A Burban1, Alexander P Safronov1,2, Ksenia O Il'inova1
1Institute of Natural Sciences and Mathematics, Ural Federal University, 19 Mira Str., Ekaterinburg 620002, Russia.
Abstract:
Gadolinium is a rare-earth element that is promising for the field of biomedicine due to its unique properties that enhance image quality, giving it high potential in targeted cancer therapy, antimicrobial treatments, etc. The disadvantage of Gd-containing materials is their high toxicity. In this work, ensembles of Fe and Al2O3 nanoparticles were fabricated by the electric explosion of wire and Gd ribbons using rapid quenching techniques. Stable Fe, Fe/Gd and Fe/Gd/Al2O3 aqueous suspensions with a Z-potential of about -54 mV were fabricated by the ball-milling mechanosynthesis of Fe (100%), Fe and Gd (70 and 30 wt. % accordingly) and Fe, Al2O3, and Gd (69, 30 and 1 wt.% accordingly). Fillers from suspensions were used for the synthesis of epoxy composites mimicking natural tissue with embedded magnetic particles. The concentration range for synthesized epoxy composites (0, 5, 10, and 15 wt.% of the filler) corresponded to the biomedical range of interest. Thin-film magnetoimpedance (MI) elements were prepared by a sputtering technique: conventional [FeNi/Cu]5/Cu/[Cu/FeNi]5 (NP) element and [FeNi/Cu]5/Cu/[Cu/P{FeNi]5} element with patterned top multilayer (SqP). They showed a maximum MI ratio of about 160% for NP and about 60% for SqP. MI sensor response was affected by the presence of filled magnetic composites in the shape of cylinders (5 mm × 4 mm) situated at about 1 mm due to the stray fields in the filler. MI response showed a linear dependence on the filler concentration for each selected position. These results open the possibility to develop new iron- and gadolinium-containing materials for simultaneous magnetic imaging and detection by magnetic field sensors, extending the functional properties of Fe/Gd materials for biomedical devices and therapies.
Related Concept Videos
Ferromagnetism
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
Magnetic Resonance Imaging
Magnetism
An individual magnetic pole cannot be isolated. No matter how small, every piece of a magnet contains a north pole and a south...
Applications Of NMR In Biology
The...