Multi-Contrast Human Brain CEST MRI at 11.7 T: First In Vivo Demonstration
Camélia Ressam1, Joseph Brégeat1, Alfredo L Lopez Kolkovsky1
1Université Paris-Saclay, CEA, CNRS, NeuroSpin, UMR 9027 BAOBAB, Gif-sur-Yvette, France.
Purpose:
To implement and evaluate chemical exchange saturation transfer (CEST) at ultra-high field on a whole-body 11.7 T scanner using parallel transmission (pTx).
Methods:
Tailored pTx CEST saturation pulses were optimized to achieve a spatially uniform target B1 + while satisfying SAR and power constraints either defined by conservatively defined radio-frequency (RF) power limits or by a virtual observation point (VOP)-based framework. The resulting pulse performance at 11.7 T was assessed through numerical simulations and compared against corresponding designs at 7 T. The proposed saturation pulses were integrated into a two-dimensional multi-slice EPI sequence. Experimental testing of the sequence was performed in vitro using metabolite-doped phantoms and in vivo in four healthy volunteers.
Results:
The pTx pulse designs optimized under VOP-based SAR constraints at 11.7 T achieved comparable performance to 7 T designs despite higher intrinsic B1 + inhomogeneity. In vitro experiments validated the sequence implementation and confirmed detection of the targeted metabolites. In vivo experiments demonstrated acceptable saturation homogeneity (nRMSE ≤ 12.1%) in a slab of thickness 1 cm, with only minimal additional improvement achieved through B1 + post-processing correction. Across the cohort, robust gray matter-white matter contrast was consistently observed for multiple CEST contrasts.
Conclusion:
VOP-based SAR-constrained pTx CEST saturation pulse design enabled robust and reproducible contrast at 11.7 T by effectively mitigating B1 + inhomogeneities while remaining within safety limits, facilitating translation to future in vivo clinical research applications.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic Stimulation (TMS).
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies for Cardiovascular System IV: CMRI