Related Experiment Video
Updated: Jul 10, 2026

A Rapid Method for Modeling a Variable Cycle Engine
Published on: August 13, 2019
Pressure surge and blade torque during shutdown of in-pipe drag-based turbines
Mohammad Karimipour Parashkooh1, Nima Hasanzadeh1, Peyman Sobhani1
1Small Scale Hydro-Devices Research Lab., School of Mechanical Engineering, College of Engineering, University of Tehran, P.O. Box 11365/4563, Tehran, Iran.
Abstract:
Hydraulic transients in drag-based in-pipe turbines during sudden operational changes can induce pressure pulsations, water hammer, cavitation, and column separation in pipeline components located both upstream and downstream of the turbine. Additionally, the torque imposed on turbine blades is a critical concern, as frequent operational changes can accelerate blade fatigue and potentially lead to structural failure. This study integrates the Method of Characteristics (MOC) and Computational Fluid Dynamics (CFD) to model transient phenomena resulting from the abrupt stoppage of a hydrodynamic in-pipe turbine. The analysis evaluates how varying deceleration rates influence pressure surges, pressure pulsations, and torque amplification on blades across different blade counts. The results demonstrate that stoppage time significantly affects torque escalation and confirm that turbine blade count strongly influences the magnitude of pressure surges during transient events. Detailed scenario analyses further reveal that specific configurations exhibit greater susceptibility to extreme pressure fluctuations, thereby creating substantial operational and reliability challenges.
More Related Videos
10:03Uncoupling Coriolis Force and Rotating Buoyancy Effects on Full-Field Heat Transfer Properties of a Rotating Channel
Published on: October 5, 2018
11:00Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
Related Concept Videos
Turbine-Governor Control
Conservation of Energy in Control Volume
For steady flow systems, the time derivative of the stored energy becomes zero since there is no energy accumulation within the control volume. This simplifies the energy equation to:
Turbulent Flow
Laminar Flow
Static, Stagnation, Dynamic and Total Pressure
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are known. The...