Related Experiment Video
Updated: Aug 5, 2026

09:03
Trabecular Meshwork Response to Pressure Elevation in the Living Human Eye
Published on: June 20, 2015
Intraocular pressure measurement in keratoconus: a narrative review
Rafael Vidal Merola1,2, Sebastião Cronemberger2
1Faculty of Medicine, Professor Antônio Carlos University Centre, UNIPAC, Juiz de Fora 36048-000, State of Minas Gerais, Brazil.
International Journal of Ophthalmology
|July 29, 2026
Summary
Measuring intraocular pressure (IOP) in keratoconus (KC) patients is challenging. Newer devices like DCT, ORA, and Corvis-ST may offer more accurate IOP readings than Goldmann applanation tonometry (GAT) in KC eyes.
Area of Science:
- Ophthalmology
- Biomedical Engineering
- Corneal Disease Research
Background:
- Accurate intraocular pressure (IOP) measurement is critical for diagnosing and managing glaucoma.
- Keratoconus (KC) is a corneal disease causing thinning, irregular astigmatism, and altered biomechanics, complicating IOP assessment.
- Goldmann applanation tonometry (GAT) may underestimate IOP in KC patients due to corneal changes.
Purpose of the Study:
- To investigate accurate IOP measurement methods for patients with keratoconus (KC).
- To evaluate newer tonometry devices for improved IOP assessment in KC.
- To address the lack of manometric studies in KC patients regarding IOP measurement.
Main Methods:
- Evaluation of advanced tonometry devices: dynamic contour tonometry (DCT), ocular response analyzer (ORA), and corneal visualization scheimpflug technology (Corvis-ST).
- Comparison of IOP measurements obtained from these devices against traditional methods in KC patients.
- Assessment of how corneal biomechanics and central corneal thickness influence IOP readings in KC.
Main Results:
- Newer devices like DCT, ORA (corneal-compensated IOP - IOPcc), and Corvis-ST (biomechanical corrected IOP - bIOP) show potential to reduce inaccuracies in IOP measurements for KC.
- These advanced methods may better account for the unique biomechanical properties and thinning of the cornea in KC.
- IOP measurements obtained by different methods are not interchangeable in KC patients.
Conclusions:
- Consistent use of the same IOP measurement device is crucial for monitoring KC patients over time.
- Advanced tonometry devices offer promising alternatives for more accurate IOP assessment in keratoconus.
- Further research is needed to understand structural and functional changes in glaucoma suspects with KC.
Related Concept Videos
Glaucoma: Overview
Glaucoma is an eye condition characterized by increased intraocular pressure that damages the retina and optic nerve, leading to irreversible blindness if left untreated. The human eye has various components, including the cornea, iris, pupil, lens, and optic nerve. Aqueous humor is secreted by the epithelium of the ciliary body in the posterior chamber and flows through the trabecular meshwork and canal of Schlemm, maintaining normal intraocular pressure. The trabecular meshwork and the canal...
Open Angle Glaucoma: Treatment
In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment
Angle-closure glaucoma, or closed-angle glaucoma, is an eye condition where the iris bulges out and blocks the iridocorneal angle, resulting in a buildup of aqueous humor and increased intraocular pressure. Immediate medical attention is necessary due to the sudden onset of symptoms. The treatment for angle-closure glaucoma includes short-term and long-term approaches. Short-term treatment involves using eye drops like pilocarpine to lower intraocular pressure by increasing aqueous humor...