Related Experiment Video
Updated: Aug 12, 2026

06:36
Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
Published on: March 14, 2025
Development and internal validation of a titanium ion-integrated diagnostic classification model for peri-implantitis
Amar Ashok Thakare1, Vaishali Mashalkar2, Kavita Gupta3
1Department of Prosthodontics, College of Dentistry, Majmaah University, Al Zulfi, Saudi Arabia.
Clinical Advances in Periodontics
|August 11, 2026
Summary
This study developed a titanium ion classification model to identify peri-implantitis risk. Higher titanium levels in fluid and serum indicate increased risk, supporting its use as a biomarker.
Area of Science:
- Biomaterials Science
- Dental Implantology
- Clinical Diagnostics
Background:
- Titanium release from dental implants is linked to peri-implantitis.
- Current disease classification models have limited integration of titanium ion data.
- Accurate classification is crucial for managing peri-implantitis.
Purpose of the Study:
- To develop and internally validate a classification model for peri-implantitis.
- To integrate titanium ion levels into a multivariable model for disease classification.
- To assess the discriminative and calibration performance of the titanium-integrated model.
Main Methods:
- Cross-sectional study with 120 participants (60 healthy, 60 peri-implantitis).
- Quantification of titanium ion concentrations in peri-implant crevicular fluid (PICF) and serum via ICP-MS.
- Multivariable logistic regression to derive the Titanium Release Score, validated with bootstrap resampling.
Main Results:
- Elevated PICF and serum titanium concentrations were significantly associated with peri-implantitis (ORs > 1.5).
- The Titanium Release Score model showed good discrimination (AUC = 0.87), with an optimism-corrected AUC of 0.83 after internal validation.
- Model calibration was acceptable (Hosmer-Lemeshow, p = 0.62).
Conclusions:
- The titanium-integrated model effectively discriminates between peri-implantitis and healthy implants.
- Titanium ion levels are independently associated with peri-implantitis, serving as a relevant risk indicator.
- Further external validation and longitudinal studies are needed for clinical application.