Related Experiment Video
Updated: Aug 30, 2026

A New Hybrid Quantitative Evaluation Model for Axillary Junctional Hemorrhage in Swine
Published on: December 6, 2024
Between Hemorrhage and Harm: Complications of the Abdominal Aortic and Junctional Tourniquet-Stabilized
Grant Gerstner1, Julie Rizzo2,3, Charles Kieffer1
1Department of Emergency Medicine, Brooke Army Medical Center, JBSA Fort Sam Houston, San Antonio, Texas.
Hemorrhage is a leading cause of preventable death after trauma, with direct pressure, appropriate tourniquet application, and volume resuscitation established as principles of hemorrhage management. In recent years, several junctional tourniquet devices have been proposed as adjuncts for groin and axillary hemorrhage control, including the Abdominal Aortic Junctional Tourniquet-Stabilized (AAJT-S), which has been marketed for non-compressible torso hemorrhage. To date, evidence supporting its use has been primarily limited to studies on cadavers, porcine models, healthy human subjects, and a few case reports. We present the case of a young adult male with multiple gunshot wounds to the pelvis and lower extremities who presented to a level I trauma center with an AAJT-S in place. Device removal in the trauma bay was followed by cardiac arrest and subsequent complications to include metabolic acidosis, compartment syndrome, rhabdomyolysis, renal and liver infarcts, pulmonary emboli, and stroke. This case highlights the potential harm of the device. We review and contrast these outcomes with the limited available literature and present our recommendation for future evaluation and caution with application of this device.
Hemorrhage is a leading cause of preventable death after trauma, with direct pressure, appropriate tourniquet application, and volume resuscitation established as principles of hemorrhage management. In recent years, several junctional tourniquet devices have been proposed as adjuncts for groin and axillary hemorrhage control, including the Abdominal Aortic Junctional Tourniquet-Stabilized (AAJT-S), which has been marketed for non-compressible torso hemorrhage. To date, evidence supporting its use has been primarily limited to studies on cadavers, porcine models, healthy human subjects, and a few case reports. We present the case of a young adult male with multiple gunshot wounds to the pelvis and lower extremities who presented to a level I trauma center with an AAJT-S in place. Device removal in the trauma bay was followed by cardiac arrest and subsequent complications to include metabolic acidosis, compartment syndrome, rhabdomyolysis, renal and liver infarcts, pulmonary emboli, and stroke. This case highlights the potential harm of the device. We review and contrast these outcomes with the limited available literature and present our recommendation for future evaluation and caution with application of this device.
Related Concept Videos
Aneurysm III: Interprofessional Care
Introduction to Hemostasis
The three phases of hemostasis involve many clotting factors present in plasma and several substances released by platelets and injured tissue cells. It is a fast, localized, and...
Vascular Spasm
Aneurysm IV: Nursing Management
Extrinsic and Intrinsic Pathways of Hemostasis
The Extrinsic Pathway
The extrinsic pathway of coagulation is typically initiated by tissue damage that exposes blood to tissue factor (TF), a protein released by the damaged tissue cells outside the blood vessels—this interaction with TF triggers biochemical reactions involving specific clotting factors. The key player here is Factor VII, which forms a...
Hemorrhagic Stroke ll: Pathophysiology