Synergistic Optimization of Reference Electrode and Solid Electrolyte for Bi/Bi2O3 Oxygen Sensors
Guodong Liu1,2, Shenghui Lu2, Bo Qin2
1School of Materials Science and Engineering, Tianjin University, Tianjin 300354, China.
Abstract:
The Bi/Bi2O3-type oxygen sensor is extensively employed for oxygen monitoring in liquid lead-bismuth eutectic (LBE)-cooled reactors, yet its low-temperature measurement accuracy remains a critical bottleneck limiting engineering deployment. This study aims to extend the lower operating temperature limit of the sensor through synergistic optimization of the reference electrode and solid electrolyte. The effects of the Bi/Bi2O3 mass ratio, filling amount, and yttria-partially stabilized zirconia (YPSZ) electrolyte wall thickness on sensor performance were systematically investigated over 300-600 °C. Electrochemical impedance spectroscopy and finite element simulations (COMSOL Multiphysics® 6.3, COMSOL Inc., Stockholm, Sweden) were used to elucidate the underlying mechanisms. The results show that the optimized sensor with a Bi/Bi2O3 mass ratio of 95:5, a filling amount of 10 g, and a YPSZ wall thickness of 1.5 mm extended the stable operating limit from 350 °C to 300 °C, achieving a relative electromotive force error of 3.13% at 300 °C and maintaining over 4000 h of drift-free service. The improved low-temperature accuracy is attributed to the reduced oxygen ion migration activation energy (0.48 eV) and lower bulk impedance of the thick-walled YPSZ after high-temperature activation. These findings provide a material optimization strategy and theoretical basis for wide-temperature-range, long-lifetime oxygen sensing in lead-based reactors.
Related Concept Videos
Potentiometry: Membrane Electrodes
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in the...