Uncertainty-aware bilevel energy storage planning for active distribution networks: A fixed-topology DistFlow-based
Zhenhua Miao1, Ziyan Li1, Yongjie Wang1,2
1School of Energy and Electrical Engineering, Qinghai University, Xining, Qinghai, China.
Abstract:
Historical renewable-load variability, voltage-security risk, and investment-operation coupling can materially change the assessed value of distribution-level energy storage. This study develops an uncertainty-aware bilevel energy storage system (ESS) planning framework in which the upper level selects a discrete siting-sizing-duration plan and the lower level solves a fixed-topology, multi-scenario mixed-integer second-order cone program (MISOCP) in which the network physics are represented by a DistFlow-SOCP formulation. An ESS-aware topology robustness check is further introduced to examine whether ESS-induced topology changes affect the planning conclusions obtained under the common-topology comparison. Complete daily load, photovoltaic, and wind observations from Denmark in 2016 and 2017 are represented as joint 72-dimensional trajectories. Input-risk-stratified historical-day reduction is examined for K = 3, 5, 10, and 20, with K = 10 used for the principal 33-bus study and K = 20 used as a higher-fidelity scenario-set check. Exhaustive evaluation of 211 alternatives identifies a 1.00 MW/ 2.00 MWh ESS at bus 24. Under K10 and the baseline fixed topology, the proposed design reduces daily TOTEX from 73,151.02 to 51,826.24 CNY/day (29.2%) relative to No ESS, raises the minimum voltage from 0.94138 to 0.95405 p.u., and reduces cumulative undervoltage exposure from 0.013528 to 0.001740 p.u.·h. Cross-year and seven-day chronological tests retain the economic and security pattern. On the released 240-bus feeder, the reference design improves voltage exposure, loading, and losses at a small incremental economic cost. These results show that historical tail conditions, common-topology attribution, and physical security metrics are important for auditable ESS planning.
Related Concept Videos
Maximum Power Flow and Line Loadability
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Power System Distribution
The transmission system is designed...
The Power Flow Problem and Solution
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the copper windings...
Energy Stored in Capacitors
By integrating the equation that relates voltage and current in a capacitor, one can derive an equation for the voltage across the capacitor at any given time. This equation is crucial in understanding and predicting the behavior of capacitors in...