Post-reconstruction method for beam hardening in computerised tomography.

O Nalcioglu, R Y Lou

    Physics in Medicine and Biology
    |March 1, 1979
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    A photo-multiplier tube-based hybrid MRI and frequency domain fluorescence tomography system for small animal imaging.

    Physics in medicine and biology·2011
    Same author

    Clinical characteristics and biomarkers of breast cancer associated with choline concentration measured by 1H MRS.

    NMR in biomedicine·2010
    Same author

    Magnetic resonance imaging evaluation of noninflammatory breast cancer with skin involvement after neoadjuvant chemotherapy.

    Annals of surgical oncology·2010
    Same author

    Combined fluorescence and X-Ray tomography for quantitative in vivo detection of fluorophore.

    Technology in cancer research & treatment·2010
    Same author

    Can proton MRS provide useful information for characterizing estrogen receptor status in breast cancer?

    Annals of oncology : official journal of the European Society for Medical Oncology·2009
    Same author

    Does breast density show difference in patients with estrogen receptor-positive and estrogen receptor-negative breast cancer measured on MRI?

    Annals of oncology : official journal of the European Society for Medical Oncology·2009
    Same journal

    PAC-Net: patch adaptive cut-off network with differentiable module-wise K-learning for robust and efficient medical image segmentation.

    Physics in medicine and biology·2026
    Same journal

    Four-dimensional on-beam computed tomography reconstruction using projection-difference images.

    Physics in medicine and biology·2026
    Same journal

    Higher-order synergy-based ranking in transcriptomic communities via latent factors and O-information.

    Physics in medicine and biology·2026
    Same journal

    Calculating biological dose distributions in hadrontherapy using GATE: the BioDose actor.

    Physics in medicine and biology·2026
    Same journal

    A 1.5 mm BGO PET detector with DOI measurement.

    Physics in medicine and biology·2026
    Same journal

    Development and validation of XrayMC: a dedicated Monte Carlo tool for X-ray imaging and radiation protection.

    Physics in medicine and biology·2026
    See all related articles

    This study introduces a novel method to correct beam hardening artifacts in computerized tomography (CT) imaging. The technique refines CT images by estimating and correcting for bone and tissue density variations, improving diagnostic accuracy.

    Area of Science:

    • Medical Imaging
    • Physics
    • Computer Science

    Background:

    • Beam hardening artifacts are a common problem in X-ray computed tomography (CT).
    • These artifacts arise from the polychromatic nature of the X-ray beam, leading to inaccurate CT number values.
    • Existing correction methods can be complex or introduce their own limitations.

    Purpose of the Study:

    • To develop and present a new method for correcting beam hardening artifacts in CT.
    • To demonstrate the effectiveness of the proposed method using a mathematical phantom.
    • To analyze the stability and potential errors associated with the correction technique.

    Main Methods:

    • An initial CT image reconstruction is performed.
    • The uncorrected image is used to estimate bone and tissue path lengths for each ray.

    Related Experiment Videos

  • A correction term is calculated and applied to the original projection data.
  • A second reconstruction is performed using the corrected projection data.
  • Main Results:

    • The proposed method successfully corrects for beam hardening artifacts in the tested mathematical phantom.
    • The final reconstructed image shows improved accuracy in CT numbers compared to the uncorrected image.
    • An examination of the method's stability reveals sensitivity to potential sources of error.

    Conclusions:

    • The presented method offers a viable approach for mitigating beam hardening artifacts in CT.
    • Further refinement may be needed to address the method's sensitivity to errors for clinical application.
    • The study provides a foundation for developing more robust artifact correction techniques in medical imaging.