Related Experiment Videos
[A simple method of blood pressure measurement in nonanesthesized rabbits]
Abstract:
A technically simple method for the continuous recording of the arterial blood pressure in the conscious rabbit is described. For the placement of the catheter it is not necessary to perform a temporally expensive preparation. The median auricular artery of the animal can be used repeatedly above all. In case the arterial mean pressure is needful as a control mechanism then this method is recommended especially.