Comparison of two commercially available isolation systems for Chlamydia trachomatis
Journal of Clinical Microbiology
|September 1, 1983
Summary
The Bartels chlamydial isolation system demonstrates superior performance in detecting Chlamydia trachomatis compared to the M. A. Bioproducts system. This finding is based on higher detection rates and inclusion counts in clinical specimens.
Area of Science:
- Microbiology
- Clinical Diagnostics
Background:
- Chlamydia trachomatis is a significant cause of sexually transmitted infections.
- Accurate and efficient laboratory detection systems are crucial for diagnosing Chlamydia trachomatis infections.
Purpose of the Study:
- To compare the diagnostic performance of two commercially available chlamydial isolation systems.
- To evaluate the efficacy of the Bartels Immunodiagnostic Supplies system versus the M. A. Bioproducts system for Chlamydia trachomatis detection.
Main Methods:
- Comparison of two cell culture isolation systems using cycloheximide-treated McCoy cell monolayers.
- Detection of Chlamydia trachomatis by iodine staining.
- Analysis of clinical specimens and passaged isolates for inclusion-forming units.
Main Results:
- The Bartels system showed significantly higher detection rates for Chlamydia trachomatis compared to the M. A. Bioproducts system (P < 0.001).
- Bartels system yielded higher inclusion counts per cover slip from both clinical specimens and passaged isolates.
- In routine clinical use, the Bartels system demonstrated higher overall isolation rates and lower contamination rates (P < 0.001).
Conclusions:
- The Bartels chlamydial isolation system is superior to the M. A. Bioproducts system for the detection of Chlamydia trachomatis.
- The Bartels system offers improved sensitivity and reliability for clinical diagnosis of Chlamydia trachomatis infections.