Bizarre repetitive discharges recorded with single fibre EMG
Abstract:
Single fibre EMG was used to record bizarre repetitive discharges in patients with chronic denervation or muscle disorders. The low variability of intervals between individual spike components on successive discharges suggests that the bizarre repetitive discharges are based on ephaptic impulse transmission from the muscle fibre starting the discharge (principal pacemaker) to the adjacent muscle fibres. The low variability of the interdischarge intervals is explained by ephaptic reactivation of the principal pacemaker by one of the fibres participating in the previous discharge (a co-pacemaker). Secondary activator fibres may spread activity to more fibres. The bizarre repetitive discharge stops when either the principal pacemaker or the co-pacemaker become sufficiently subnormal to block. The co-pacemaker may be missing in cases of low frequency bizarre repetitive discharges, particularly in those with irregular interdischarge intervals.
More Related Videos
09:34Use of In Vivo Single-fiber Recording and Intact Dorsal Root Ganglion with Attached Sciatic Nerve to Examine the Mechanism of Conduction Failure
Published on: August 27, 2019
04:30Stimulated Single Fiber Electromyography (SFEMG) for Assessing Neuromuscular Junction Transmission in Rodent Models
Published on: March 8, 2024