Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Particle image-resolution test object.

A Goldstein, W Clayman

    Journal of Ultrasound in Medicine : Official Journal of the American Institute of Ultrasound in Medicine
    |May 1, 1983
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Efficacy of self-management program associated with a spa therapy for knee osteoarthritis patients (GETT 2): a research protocol for a randomized trial.

    Trials·2023
    Same author

    A bright γ-ray flare interpreted as a giant magnetar flare in NGC 253.

    Nature·2021
    Same author

    Involvement of the Spinal Cord in Primary Mitochondrial Disorders: A Neuroimaging Mimicker of Inflammation and Ischemia in Children.

    AJNR. American journal of neuroradiology·2021
    Same author

    Use of Co<sup>2+</sup>:MgAl<sub>2</sub>O<sub>4</sub> transparent ceramics in passive Q-switching of an Er:Glass laser at 1.534 µm.

    Optics express·2020
    Same author

    The Perirolandic Sign: A Unique Imaging Finding Observed in Association with Polymerase γ-Related Disorders.

    AJNR. American journal of neuroradiology·2020
    Same author

    Prediction-based neural mechanisms for shielding the self from existential threat.

    NeuroImage·2019
    Same journal

    Translating AI-Based Biopsy Sparing into Clinically Actionable Decision-Making for BI-RADS 4A+ Breast Lesions.

    Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine·2026
    Same journal

    Comparative Study of Microvascular Flow and Viscoelasticity Imaging in Monitoring Renal Allograft Function.

    Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine·2026
    Same journal

    Deep Learning for Automated Infant Hip Ultrasound: Toward Robust Generalization across Disease Spectrum and Devices.

    Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine·2026
    Same journal

    Ultrasound Assessment of the Fetal Pancreas in Normal and Abnormal Pregnancies: A Narrative Review.

    Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine·2026
    Same journal

    Placental Assessment Using Microvascular Flow Imaging: Reference Ranges and Clinical Application.

    Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine·2026
    Same journal

    Clinical Considerations of Shear Wave Elastography for Differentiating Benign from Malignant Breast Lesions.

    Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine·2026
    See all related articles

    A novel blur technique and test object improve high-subject-contrast image resolution measurement. This method simplifies assessment, providing axial and lateral resolution data from a single scan for all real-time scanners.

    Area of Science:

    • Medical imaging
    • Ultrasound technology
    • Image resolution assessment

    Background:

    • Accurate measurement of image resolution is crucial for diagnostic ultrasound.
    • Existing methods for assessing high-subject-contrast image resolution can be complex and time-consuming.

    Purpose of the Study:

    • To propose a new blur definition and measurement technique for high-subject-contrast image resolution.
    • To develop and test a novel test object for this technique.

    Main Methods:

    • Developed a new test object using plastic particles in a gelatin base.
    • Optimized particle size and concentration for clinical transducer frequencies.
    • Acquired test images using static and real-time transducers with varying focal properties.

    Related Experiment Videos

    Main Results:

    • The developed test object effectively indicated the focal zone of optimum image resolution.
    • The technique proved feasible across different transducer types and focal properties.
    • The test object demonstrated simplicity and ease of use.

    Conclusions:

    • The proposed blur technique offers a simple and effective method for measuring high-subject-contrast image resolution.
    • The new test object is versatile, suitable for all real-time scanners.
    • A single scan provides comprehensive axial and lateral resolution data at all depths.