Optocardiography and Electrophysiology Studies of Ex Vivo Langendorff-perfused Hearts
Published on: November 7, 2019
Beat-to-beat left ventricular performance assessed from the equilibrium cardiac blood pool using a computerized
Abstract:
The feasibility, accuracy and reproducibility of continuous beat-to-beat evaluation of left ventricular performance with a computerized nonimaging scintillation probe was assessed in 71 patients. This portable instrument has enough sensitivity to generate a real-time relative left ventricular volume curve using the labeled equilibrium blood pool without electrocardiographic gating. The probe was positioned at the left ventricular and background regions of interest using a systematic series of computerized algorithms and operator routines that were developed and standardized during the initial phase of this study. In each patient, left ventricular ejection fraction was calculated manually from the strip-chart recording in 10 consecutive sinus beats. Beat-to-beat left ventricular ejection fraction determined by the probe correlated well with first-pass studies obtained using a computerized multicrystal scintillation camera (r = 0.92). There was no systematic over- or underestimation, and the correlation was evident over a wide range of first-pass values (15-81%). There was excellent agreement between initial and repeat analyses (n = 58, r = 0.97) and between initial and repeat studies (n = 48, r = 0.94). The absolute variability of beat-to-beat ejection fraction measurements determined from all 710 beats was +/- 5.9% (expressed in ejection fraction units as +/- 2 SD). This technique should provide a reliable means of addressing pathophysiologic questions that require sampling of data directly on a beat-to-beat basis.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.