Related Experiment Video
Updated: Aug 12, 2026

MRI and PET in Mouse Models of Myocardial Infarction
Published on: December 19, 2013
Rest myocardial perfusion/metabolism imaging using simultaneous dual-isotope acquisition SPECT with
D Delbeke1, S Videlefsky, J A Patton
1Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee 37232-2675, USA.
Unlabelled:
The purpose of this study was to develop a dual-isotope simultaneous acquisition (DISA) protocol using a multihead SPECT camera equipped with an ultrahigh-energy (UHE) collimator to evaluate simultaneously rest cardiac perfusion and metabolism with 99mTc-MIBI/18FDG.
Methods:
Physical measurements were first performed with phantoms to develop the acquisition protocol. Fifteen patients underwent DISA-SPECT with 99mTc-MIBI/18FDG to validate the protocol. To evaluate the quality of the 99mTc-MIBI images acquired with the UHE collimator, four patients underwent a resting 99mTc-MIBI scan acquired with a high-resolution, low-energy collimator prior to DISA-SPECT.
Results:
With a window of 20% for both photopeaks and a 99mTc/18F concentration ratio of 3.2:1, the spillover from 18F into the 99mTc window is 6% of the counts in the window for normal subjects. Phantom images clearly demonstrated defects measuring 2 x 1 and 2 x 0.5 cm. Technetium-99m-MIBI images obtained with the UHE and high-resolution collimators provided similar diagnostic information. Using a stenosis of > 70% as criteria to diagnose coronary artery disease, DISA-SPECT had a sensitivity of 100% and a positive predictive value of 93%.
Conclusion:
Simultaneous evaluation of rest myocardial perfusion/metabolism with a multihead SPECT camera equipped with an UHE collimator is possible using 99mTc-MIBI/18FDG with a dual-isotope simultaneous acquisition protocol.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET