Related Experiment Video
Updated: Jul 24, 2026

An Objective and Child-friendly Assessment of Arm Function by Using a 3-D Sensor
Published on: February 12, 2018
Shooting performance is related to forearm temperature and hand tremor size
M Lakie1, F Villagra, I Bowman
1School of Sport and Exercise Sciences, University of Birmingham, Edgbaston, UK.
Abstract:
The changes in postural tremor of the hand and the subsequent effect on shooting performance produced by moderate cooling and heating of the forearm were studied in six subjects. Cooling produced a large decrease in tremor size of the ipsilateral hand, whereas warming the limb produced an increase in tremor size. Cooling or warming the forearm did not change the peak frequency of tremor significantly, which was quite stable for each subject. The improvement in shooting performance after cooling the forearm, as measured by grouping pattern of the shots, reached statistical significance and warming caused a significant worsening. This measure of performance was shown to correlate (r = 0.776) inversely with tremor size. The causes and implications of these changes are discussed. It is suggested that local cooling may be useful for people who wish temporarily to reduce tremor in order to improve dexterity for shooting and for other purposes.
Related Concept Videos
Factors Affecting Body Temperature
Factors may include:
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Muscles that Move the Forearm
Forearm Flexors
The biceps brachii, brachialis, and brachioradialis are forearm flexors. The biceps brachii is made up of two heads. Its long head originates at the supraglenoid tubercle of the scapula, whereas that of the short head is...
Muscles of the Forearm that Move the Hand and Fingers
Anterior Compartment
The anterior compartment muscles originate from the humerus. They primarily function as flexors and are also known as flexor muscles. They typically insert on the carpals, metacarpals, and phalanges. The superficial layer includes the flexor carpi radialis,...

