Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Phased array coils for upper extremity MRA

J W Monroe1, P Schmalbrock, D G Spigos

  • 1Department of Radiology, Ohio State University, Columbus, USA.

Magnetic Resonance in Medicine
|February 1, 1995
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Basal Ganglia Iron in Patients with Multiple Sclerosis Measured with 7T Quantitative Susceptibility Mapping Correlates with Inhibitory Control.

AJNR. American journal of neuroradiology·2015
Same author

Dose comparison of single versus double dose in contrast-enhanced magnetic resonance angiography of the renal arteries: intra-individual cross-over blinded trial using Gd-DTPA.

European radiology·2008
Same author

Temporal bone dissection simulation--an update.

Studies in health technology and informatics·2004
Same author

Partial tear of pectoralis major muscle masquerading as a breast mass in an 87-year-old woman. A case report.

Acta radiologica (Stockholm, Sweden : 1987)·2002
Same author

Comparison of autopsy, X-ray, and M.R.I. findings following a low speed impact to the shoulder.

Annual proceedings. Association for the Advancement of Automotive Medicine·2002
Same author

Delivering images to the operating room: a web-based solution.

Journal of digital imaging·2002
Same journal

A Comparison of Tissue Property Values Estimated Using Conventional Cardiac MRF and MT-Cardiac MRF.

Magnetic resonance in medicine·2026
Same journal

Dependence of the Extra-Cellular Diffusion Coefficient on the Fractions of Neurites and Cell Bodies in Gray Matter.

Magnetic resonance in medicine·2026
Same journal

Triple-Pulse <sup>23</sup>Na MRI Sequence (TriNa) for Simultaneous Acquisition of Spin-Density-Weighted and Fluid-Attenuated Images.

Magnetic resonance in medicine·2026
Same journal

Evaluation of Phantom Doping Materials in Quantitative Susceptibility Mapping.

Magnetic resonance in medicine·2026
Same journal

Design of an 8-Channel Transmit 32-Channel Receive 11.7T Head Coil and Evaluation of SNR Gains.

Magnetic resonance in medicine·2026
Same journal

The Potential for Absolute Temperature Imaging Based on Brain Metabolites Using an FID-Shifting Approach in Gradient Echo Planar Spectroscopic Imaging (GREPSI).

Magnetic resonance in medicine·2026
See all related articles

A new phased array coil enhances upper extremity vascular imaging for dialysis patients. This improved signal-to-noise ratio (SNR) allows for clearer visualization of blood vessels throughout the entire arm.

Area of Science:

  • Medical Imaging
  • Biomedical Engineering
  • Vascular Imaging

Background:

  • Dialysis patients often require imaging of upper extremity vasculature.
  • Existing imaging methods may have limitations in signal-to-noise ratio (SNR) for detailed vascular assessment.
  • A dedicated coil can potentially improve image quality and diagnostic capabilities.

Purpose of the Study:

  • To develop and evaluate a phased array coil for improved upper extremity vascular imaging.
  • To assess the signal-to-noise ratio (SNR) improvements offered by the new coil compared to the body coil.
  • To demonstrate the coil's utility in visualizing upper extremity vasculature using advanced imaging techniques.

Main Methods:

  • Construction of a specialized phased array coil for upper extremity imaging.

Related Experiment Videos

  • Quantitative SNR measurements on a homogeneous phantom, comparing the phased array coil with the body coil at various depths.
  • In vivo SNR measurements in healthy volunteers.
  • Acquisition of 2D-time-of-flight (2DTOF) angiography images of the upper extremity vasculature.
  • Assessment of blood flow velocity using CINE-phase contrast imaging.
  • Main Results:

    • The phased array coil demonstrated significant SNR improvement over the body coil, with a factor of 7 near the coil and a factor of 2 at a depth of 6-7 cm.
    • In vivo SNR measurements corroborated the phantom findings.
    • 2D-time-of-flight (2DTOF) angiography successfully generated images of the upper extremity vasculature.
    • CINE-phase contrast imaging allowed for the assessment of blood flow velocity.

    Conclusions:

    • The developed phased array coil provides superior SNR for upper extremity vascular imaging in dialysis patients.
    • The coil enables comprehensive imaging of the entire upper extremity vasculature.
    • This technology holds promise for enhanced diagnosis and monitoring of vascular conditions in dialysis patients.