Related Experiment Video
Updated: Aug 17, 2026

A Protocol of Manual Tests to Measure Sensation and Pain in Humans
Published on: December 19, 2016
Rationale for a personal monitor for heat strain
1College of Public Health, University of South Florida, Tampa 33612-3805.
Abstract:
Worker heat-stress exposures can be controlled for short periods above the threshold limit value (TLV) by self-assessment, if the worker can avoid overexposure based on excessive heart rate and/or excessive core temperature. A socially acceptable surrogate for core temperature and a measure of heart rate are objective measures that can increase the reliability of the self-assessment decision. This article describes a surface-mounted temperature sensor developed to indicate when rectal temperature reaches a safe limit. Protective criteria were established for temperature sensor alert limits. A fixed threshold for heart rate may cause premature alerts during bursts of activity and miss lower, but sustained, heart rates that represent significant physiological strain. For these reasons, heart rate criteria based on seven moving-time averages also were developed. The criteria are based on a relationship between heart rate and endurance time. The temperature sensor and heart rate criteria form the basis of a real-time personal monitor for heat strain.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Holter Monitor: 24-Hour Monitoring

