In Vivo Surface Electrocardiography for Adult Zebrafish
Published on: August 1, 2019
Fast and reliable QRS alignment technique for high-frequency analysis of signal-averaged ECG
O J Escalona1, R H Mitchell, D E Balderson
1Department of Electrical & Electronic Engineering, University of Ulster, Northern Ireland, UK.
Abstract:
The process of QRS alignment as required in signal-averaged ECG can impose serious limitations on the spectral range of the signal output. This effect depends basically on the particular alignment technique being used and on the level and type of noise present in the recorded ECG. In clinical studies where a wide-band (1000 Hz) ECG averager is required, the conventional QRS alignment technique, based on maximum coherence matching (MCM) with a template beat, may not perform consistently well. An alternative QRS alignment technique based on the accurate detection of a single fiducial point (SFP) in the bandpass filtered (3-30 Hz) QRS complex was developed. Using computer simulation methods, a comparative assessment of the frequency bandwidths (3 dB points) offered by both MCM and SFP techniques as a function of noise level (15-100 muRMS) and type (EMG and 50 Hz interference), was carried out. The results of the comparative assessment indicated a better performance by the SFP technique in all cases of noise. Hence, the SFP technique would perform more reliably for high-frequency analysis of a noisy ECG, especially when 50 Hz interference is high. Furthermore, SFP is considerably faster than MCM (about four times) when implemented digitally, and its analogue realisation is feasible. The SFP technique is suitable for late-potential analysis in the signal-averaged ECG.
Related Concept Videos
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias