Precision, accuracy, and data acceptance criteria in biopharmaceutical analysis
Related Experiment Video
Updated: Nov 8, 2026

Selected Reaction Monitoring Mass Spectrometry for Absolute Protein Quantification
Published on: August 17, 2015
1Department of Pharmacy and Pharmaceutics, Virginia Commonwealth University, Richmond 23298-0533.
Abstract:
Accuracy and precision are the most important criteria in the assessment of an analytical method, and monitoring quality control during sample analysis is essential to ensure the validity of reported results. Various approaches to testing accuracy, precision, and quality control were applied to 10 analytes from seven chromatographic bioanalytical methods. These methods include fixed interval bias and significance testing for accuracy; fixed interval percentage relative standard deviation (%RSD) and analysis of variance (ANOVA) approaches for precision; +/- 20% fixed range, 99% confidence interval, multiple rules, and range chart for individuals approaches for quality control acceptance criteria. Quality control approaches were also applied to the entire run and to a bracketed approach whereby results are considered valid only if bracketed by acceptable quality control. Accuracy and precision were assessed for six runs of each analyte at three concentrations established to represent the calibration range of the analytical method. Quality control acceptance criteria were evaluated using all data sets from each of the analytical methods collected during the course of running various numbers of real samples. The data suggest that the fixed interval bias criteria for accuracy was a more liberal method of accuracy assessment because three of the seven methods would have been rejected according to the significance testing criteria whereas all were acceptable by the fixed internal bias criteria. Precision can be effectively assessed for between- and within-run data by criteria set on unconfounded %RSD values or by separation of the sources of variation using an ANOVA approach applied to confounded data.(ABSTRACT TRUNCATED AT 250 WORDS)
More Related Videos
07:52Detection of Antibodies That Neutralize the Cellular Uptake of Enzyme Replacement Therapies with a Cell-based Assay
Published on: September 10, 2018
04:50Reproducibility and Harmonization in Research Using Biological Standards: The Example of Platelet Agonist Collagen-Related Peptide
Published on: August 4, 2023
Related Concept Videos
Data Validation
Key parameters for method validation include:
Clinically Relevant Drug Product Specifications: Methods of Establishment
Uncertainty in Measurement: Accuracy and Precision
Drug Dissolution: Requirements and Profile Comparison
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Accuracy and Precision