Related Experiment Video
Updated: Jul 12, 2026

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Accuracy and repeatability of a pocket turbine spirometer: comparison with a rolling seal flow-volume spirometer
L P Malmberg1, J Hedman, A R Sovijärvi
1Department of Pulmonary Medicine, Helsinki University Hospital, Finland.
Abstract:
The accuracy and repeatability of a recently introduced pocket spirometer (Micro Spirometer; Micro Medical Instruments Ltd, Rochester, UK) was evaluated. FEV1 and FVC values obtained with this instrument were compared with those measured with a rolling-seal flow-volume spirometer (CPI 220 with microcomputer) in 31 patients and 11 healthy volunteers. In the whole material, expressed as mean +/- SD, the pocket spirometer recorded 0.44 +/- 0.23 l (13 +/- 7%) smaller values for FEV1 (P < 0.001) and 0.64 +/- 0.48 l (15 +/- 11%) smaller values for FVC (P < 0.001) than the rolling-seal spirometer. The short-term repeatability of the measurements expressed as the coefficient of variation of repeated measurements using the pocket spirometer was 2.2% for FEV1 and 2.3% for FVC in a series of 10 healthy subjects and 10 patients with COPD. It is concluded that the underestimation of FEV1 and FVC of the pocket spirometer was too large and inconsistent for the device to be used interchangeably with conventional spirometers. However, the repeatability of the measurements with the pocket spirometer is close to that reported previously for flow-volume spirometry. Thus the pocket spirometer may be suitable in assessing acute changes of spirometric indices e.g. during provocation tests or during patient follow-up in asthma.
Related Concept Videos
Uncertainty in Measurement: Accuracy and Precision
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Pipe Flowrate Measurement
The orifice meter is a simple,...

