Comparison of three keratometry instruments

D G Tennen1, R H Keates, C Montoya

  • 1Department of Ophthalmology, University of California, Irvine 92717, USA.

Journal of Cataract and Refractive Surgery
|July 1, 1995
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Transvaginal ultrasound for detecting parametrial involvement in suspected deep pelvic endometriosis: updated meta-analysis.

Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology·2025
Same author

[Translated article] Penetrating Lesion on the Face.

Actas dermo-sifiliograficas·2024
Same author

Developing Bioactive Dental Resins for Restorative Dentistry.

Journal of dental research·2023
Same author

Penetrating Lesion on the Face.

Actas dermo-sifiliograficas·2023
Same author

Epigenetic control of the EWS‑FLI1 promoter in Ewing's sarcoma.

Oncology reports·2020
Same author

Porokeratosis-Like Grover Disease: More Than an Acantholytic Pattern.

Actas dermo-sifiliograficas·2018
Same journal

Light adjustable lens implantation with cataract surgery in eyes with macular pathology.

Journal of cataract and refractive surgery·2026
Same journal

Comment on: Use of intracameral antibiotics prophylaxis in patients with posterior capsule rupture during cataract surgery: systemic review and meta-analysis.

Journal of cataract and refractive surgery·2026
Same journal

Dehydration and Rehydration Behavior of Ultra-High-Fluence Extracorporeal Cross-Linked Corneal Allogenic Intrastromal Ring Segments (ECO-CAIRS).

Journal of cataract and refractive surgery·2026
Same journal

Multimodal Deep Learning for Predicting Postoperative Vault and Selecting ICL Sizes Using AS-OCT and UBM Images.

Journal of cataract and refractive surgery·2026
Same journal

Reply: Evaluating large language models vs residents in cataract and refractive surgery: comparative analysis using the American Academy of Ophthalmology Self-Assessment Program.

Journal of cataract and refractive surgery·2026
Same journal

Comment on: Evaluating large language models vs residents in cataract and refractive surgery: comparative analysis using the American Academy of Ophthalmology Self-Assessment Program.

Journal of cataract and refractive surgery·2026
See all related articles

Newer keratometers and corneal topography systems show comparable reliability to the Javal-Schiotz instrument. These advanced tools offer greater convenience and efficiency in clinical eye care settings.

Area of Science:

  • Ophthalmology
  • Optometry
  • Biomedical Engineering

Background:

  • Accurate corneal curvature measurement is crucial for refractive error correction and surgical planning.
  • The Javal-Schiotz keratometer is considered the gold standard for assessing corneal power.
  • Advancements in ophthalmic instrumentation have introduced new keratometers and corneal topography systems.

Purpose of the Study:

  • To compare the measurement reliability of three modern keratometers and a corneal topography system against the Javal-Schiotz keratometer.
  • To evaluate the accuracy and clinical utility of newer corneal measurement devices.

Main Methods:

  • A comparative study involving 200 eyes from 100 patients.
  • Simultaneous measurement of corneal curvature using the Javal-Schiotz keratometer, three newer keratometers, and a corneal topography system.

Related Experiment Videos

  • Analysis focused on the steepest and flattest powers within the central 3 mm of the cornea.
  • Main Results:

    • No statistically significant difference in measurement reliability was found between the newer devices and the Javal-Schiotz keratometer.
    • The newer keratometers and corneal topography system demonstrated comparable accuracy to the gold standard.
    • The modern instruments were noted to be more convenient and efficient in certain clinical scenarios.

    Conclusions:

    • Modern keratometers and corneal topography systems provide reliable and accurate corneal measurements comparable to the Javal-Schiotz.
    • These newer technologies offer practical advantages in clinical efficiency and ease of use.
    • The findings support the adoption of updated instrumentation for routine ophthalmic examinations.