Related Experiment Videos
[Single lag screw osteosynthesis for management of mandibular angle fractures]
H Wagener1, R Dammer, H Niederdellmann
1Klinik und Poliklinik für Mund-, Kiefer- und Gesichtschirurgie, Regensburg.
Abstract:
80 patients with 83 fractures of the mandibular angle were treated by lag screw fixation. The screws were placed through a transoral incision with transbuccal trochar instrumentation. No maxillomandibular fixation was used. Complications occurred in 12 fractures (14%), of which 5 (6%) required secondary surgical intervention. In all cases bony union was achieved 6 months postoperatively. Indications and advantages of the technique are discussed.