Related Experiment Videos
Determination of short-chain aliphatic, oxo- and hydroxy-acids in drinking water at low microgram per liter
S Peldszus1, P M Huck, S A Andrews
1Department of Civil Engineering, University of Waterloo, Ontario, Canada.
Abstract:
A fast and reliable ion chromatography method has been developed and applied to study the formation and consumption of organic acid ozonation by-products in a drinking water treatment plant. Water samples are injected directly into the ion chromatograph using a large sample loop (740 mu l) without any sample preparation step other than possibly filtration. Organic and inorganic anions are determined by separation on a high-capacity anion-exchange column followed by conductivity detection. The average recovery for the organic acids investigated (beta-hydroxybutyric, acetic, glycolic, butyric, formic, alpha-ketobutyric and pyruvic acid) ranged from 96 to 105%, and their method detection limits ranged from 1 to 5 mu g/l. When applied to samples taken from a drinking water treatment plant, the method proved to be reliable.