A conceptual basis for pacing waveforms

B G Cleland1

  • 1Telectronics Pacing Systems, Sydney, Australia.

Pacing and Clinical Electrophysiology : PACE
|August 1, 1996
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

An analysis of the effect of retinal ganglion cell impulses upon the firing probability of neurons in the dorsal lateral geniculate nucleus of the cat.

Brain research·2001
Same author

Tailoring of variability in the lateral geniculate nucleus of the cat.

Biological cybernetics·1996
Same author

A conceptual basis for defibrillation waveforms.

Pacing and clinical electrophysiology : PACE·1996
Same author

The rod-cone shift and its effect on ganglion cells in the cat's retina.

Vision research·1992
Same author

Effects of selective pressure block of Y-type optic nerve fibers on the receptive-field properties of neurons in the striate cortex of the cat.

Visual neuroscience·1992
Same author

Effects of selective pressure block of Y-type optic nerve fibers on the receptive-field properties of neurons in area 18 of the visual cortex of the cat.

Visual neuroscience·1992
Same journal

A Case of Permanent Pacemaker Implantation via the Epicardial Approach Using the 3830 Lead in an 11-Day-Old Neonate (With Follow-Up of the Above Case).

Pacing and clinical electrophysiology : PACE·2026
Same journal

Cryoballoon Versus Radiofrequency Ablation for Persistent Atrial Fibrillation: Meta-Analysis of Randomized Trials.

Pacing and clinical electrophysiology : PACE·2026
Same journal

Tilt Test Duration in Suspected Vasovagal Syncope: Temporal Patterns and Diagnostic Yield in Patients From Central China.

Pacing and clinical electrophysiology : PACE·2026
Same journal

Combined Leadless Pacing and Subcutaneous ICD Therapy in Long QT Syndromes.

Pacing and clinical electrophysiology : PACE·2026
Same journal

Association of Anesthesia Modality With Procedural Parameters and Clinical Outcomes in PVI for Atrial Fibrillation.

Pacing and clinical electrophysiology : PACE·2026
Same journal

Zero-Fluoroscopy Cryoballoon Ablation for Paroxysmal Atrial Fibrillation in a Patient With Dextrocardia: A Case Report.

Pacing and clinical electrophysiology : PACE·2026
See all related articles

A new model evaluates pacemaker stimulus waveforms by simulating heart voltage. It identifies optimal pacing duration for minimal voltage, aiding device optimization.

Area of Science:

  • Biomedical Engineering
  • Cardiovascular Physiology
  • Medical Device Technology

Background:

  • Pacemaker efficacy is crucial for cardiac rhythm management.
  • Stimulus waveform characteristics significantly impact pacing effectiveness.
  • Understanding the heart's electrical response to pacing is essential for device design.

Purpose of the Study:

  • To develop a computational model for evaluating cardiac pacing efficacy.
  • To visualize the effective voltage dynamics within the heart during pacing.
  • To determine optimal stimulus durations for minimal pacing energy.

Main Methods:

  • A first-order time constant model of the heart was employed.
  • The model simulates voltage changes within the heart following a pacemaker stimulus.

Related Experiment Videos

  • Analysis focused on the peak voltage time and decay characteristics.
  • Main Results:

    • The model demonstrates rapid voltage rise and slower decay for capacitor-discharged pacemaker pulses.
    • Optimal pacing duration was identified as the time to peak voltage.
    • Model characteristics illustrate effects of output capacitor, lead impedance, and heart time constant on pacing parameters.

    Conclusions:

    • The developed model provides a method for assessing pacing waveform efficacy.
    • Optimal pacing duration is directly related to stimulus waveform and cardiac properties.
    • This model aids in optimizing pacemaker performance and reducing energy consumption.