Low-dose tomographic techniques for dental implant planning

A Ekestubbe1, K Gröndahl, S Ekholm

  • 1Department of Oral Diagnostic Radiology, Göteborg University, Faculty of Odontology, Sweden.

The International Journal of Oral & Maxillofacial Implants
|September 1, 1996
PubMed
Summary

Low-dose computerized tomography (CT) offers comparable image quality for preimplant imaging of the jaw. Both CT and conventional spiral tomography can achieve effective low-dose mandibular preimplant imaging.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Augmented reality glasses as a new tele-rehabilitation tool for home use: patients' perception and expectations.

Disability and rehabilitation. Assistive technology·2020
Same author

Diffusion tensor imaging in multiple sclerosis at different final outcomes.

Acta neurologica Scandinavica·2017
Same author

Clinically isolated syndromes with no further disease activity suggestive of multiple sclerosis at the age of population life expectancy.

Multiple sclerosis (Houndmills, Basingstoke, England)·2013
Same author

Update of the original HDLS kindred: divergent clinical courses.

Acta neurologica Scandinavica·2011
Same author

Percentage signal recovery derived from MR dynamic susceptibility contrast imaging is useful to differentiate common enhancing malignant lesions of the brain.

AJNR. American journal of neuroradiology·2011
Same author

A contrast correction method for dental images based on histogram registration.

Dento maxillo facial radiology·2010

Area of Science:

  • Dentistry
  • Radiology
  • Medical Imaging

Background:

  • Preimplant imaging is crucial for dental implant success.
  • Computerized tomography (CT) and conventional spiral tomography are used for preimplant assessments.
  • Optimizing radiation dose while maintaining image quality is essential.

Purpose of the Study:

  • To compare image quality of preimplant computerized tomography (CT) with varying radiation doses and scanning modes against conventional spiral tomography.
  • To evaluate the visibility of the mandibular canal and alveolar bone crest in different imaging scenarios.

Main Methods:

  • Evaluated image quality from preimplant CT scans at radiation doses from 40 to 280 mAs.
  • Compared standard, helical axial, 15-degree angled, and frontal CT scanning modes.

Related Experiment Videos

  • Assessed visibility of anatomical structures in mandibular jaw segments using CT and conventional spiral tomography (Scanora).
  • Main Results:

    • Radiation dose had minimal impact on CT image quality, except for frontal scanning where a small difference was statistically significant.
    • Significant differences in image quality were observed among various CT scanning modes.
    • CT imaging showed highly significant differences compared to conventional spiral tomography.

    Conclusions:

    • Low-dose preimplant tomography of the mandible is feasible using CT with reduced radiation doses.
    • Conventional spiral tomography also provides a viable option for low-dose mandibular preimplant imaging.
    • Image quality is influenced by CT scanning mode and the imaging modality used.