Related Experiment Video
Updated: Aug 24, 2026

Technical Aspects of the Mouse Aortocaval Fistula
Published on: July 11, 2013
Aortocaval fistulae: a percutaneous model and treatment with stent grafts in sheep
F Boudghène1, M Sapoval, M Bonneau
1Vascular and Interventional Unit, Department of Radiology, Hôpital Tenon, Paris, France.
Background:
Treatment of aortocaval fistulae (ACFs) by open surgery is known to be a high-risk procedure. In this experimental study, we developed a percutaneous model of ACF to test a new nonsurgical method of treatment of ACF using endovascular stent grafts.
Methods And Results:
An ACF was created percutaneously in eight sheep. Via a combined venous and arterial femoral approach, angioplasty balloons were inserted to occlude the infrarenal aorta and inferior vena cava (IVC). The IVC was punctured through the lateral aortic wall with a transjugular liver biopsy needle. The fistulous tract was then dilated with an 8-mm angioplasty balloon, and the animal was heparinized. Two weeks later, a 10-mm Cragg-Endopro-Stent was inserted into the aorta at the level of the fistula via a percutaneous femoral approach. ACFs were successfully created in all animals, with rapid dye shunt through the fistula and a 20% increase in cardiac pulsations. Follow-up angiograms at 2 weeks showed a patent ACF, and stent implantation excluded the fistula in every case. Angiographic and pathological examinations up to 6 months demonstrated normal aortic patency and persistent exclusion of the fistulae.
Conclusions:
ACFs were effectively treated by endovascular grafting of the aorta. The animal model and the stenting procedures were both performed percutaneously.