Unlabelled:
The purpose of this study was to evaluate the properties of 4-fluoro-3-[131I]iodobenzylguanidine ([131I]FIBG), a potential neuroendocrine tumor and myocardial imaging radiopharmaceutical.
Methods:
The binding of [131I]FIBG and [125I]MIBG was compared in vitro using the SK-N-SH human neuroblastoma cell line. The role of the active uptake-1 mechanism was investigated by determining the effect on cell binding of desipramine (DMI), ouabain, norepinephrine (NE), unlabeled MIBG and FIBG and by incubation at 4 degrees C. Finally, the tissue distributions of [131I]FIBG and [125I]MIBG were compared in normal mice.
Results:
The specific binding of [131I]FIBG remained fairly constant (45%-60%) over a 2-3-log activity range and consistently was 11%-14% higher (p < 0.05) than that of [125I]MIBG. The uptake of [131I]FIBG was reduced to 13% of control values by 1.5 microM DMI, to 31% by 1 mM ouabain, to 8% by lower temperature, to 8% by 50 microM NE and to 6% and 5% by 10 microM each of unlabeled MIBG and FIBG, respectively. The amount of [131I]FIBG retained by SK-N-SH cells was significantly higher than that of [125I]MIBG with the maximum difference observed at 72 hr. In mice, the uptake of [131I]FIBG was higher than that of [125I]MIBG not only in target tissues (heart and adrenals) but also in many other normal tissues; conversely, thyroidal uptake of [131I]FIBG was 2-3-fold lower than that of [125I]MIBG. The uptake of [131I]FIBG in the heart and adrenals was reduced by DMI.
Conclusion:
Iodine-131-FIBG is an analog of MIBG with prolonged binding to neuroblastoma cells in vitro and retention in the myocardium in vivo.
More Related Videos
07:26Synthesis of 68Ga Core-doped Iron Oxide Nanoparticles for Dual Positron Emission Tomography /(T1)Magnetic Resonance Imaging
Published on: November 20, 2018
09:34Dynamic Imaging of Chimeric Antigen Receptor T Cells with [18F]Tetrafluoroborate Positron Emission Tomography/Computed Tomography
Published on: February 17, 2022
Related Concept Videos
Magnetic Resonance Imaging
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies IV: Magnetic Resonance Imaging