Related Experiment Video
Updated: Oct 17, 2026

Matrix-assisted Laser Desorption/Ionization Time of Flight (MALDI-TOF) Mass Spectrometric Analysis of Intact Proteins Larger than 100 kDa
Published on: September 9, 2013
Use of 2,6-dihydroxyacetophenone for analysis of fragile peptides, disulphide bonding and small proteins by
J J Gorman1, B L Ferguson, T B Nguyen
1Biomolecular Research Institute, Parkville, Victoria, Australia.
Abstract:
Several peptides were shown to undergo fragmentation during matrix-assisted laser desorption/ionization time-of-flight mass spectrometry to a degree which complicated their analysis using alpha-cyano-4-hydroxycinnamic acid (CHCA) as a matrix, even at threshold laser irradiance. These peptides included synthetic peptides, peptides isolated from viral proteins and a phosphopeptide from beta-casein (residues 33-48). The excessive fragmentation occurred usually as a post-source phenomenon; however, in-source fragmentation was also observed. The combined effects of in-source and post-source fragmentation of one peptide studied led to a failure to observe the protonated molecule of this peptide in reflector mode analysis. The phosphopeptide studied exhibited a high degree of beta-elimination of phosphate. It was demonstrated that the fragility exhibited by these peptides in CHCA, including beta-elimination of phosphate from serine, was not evident with a matrix comprising 2,6-dihydroxyacetophenone (DHAP) and di-ammonium hydrogen citrate (DAHC). The DHAP/DAHC matrix was also adapted for direct analysis of peptides from an acidic reducing milieu containing tris(2-carboxyethyl)phosphine. The molecular weight of equine cytochrome c was determined with a relatively high degree of accuracy (experimental M(r) = 12360.2 +/- 1.4 Da compared to the theoretical M(r) = 12360.09 Da) using DHAP/DAHC as a matrix for reflector mode analysis.
More Related Videos
09:38Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013
08:16Optimal Preparation of Formalin Fixed Samples for Peptide Based Matrix Assisted Laser Desorption/Ionization Mass Spectrometry Imaging Workflows
Published on: January 16, 2018
Related Concept Videos
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Matrix-Assisted Laser Desorption Ionization (MALDI)