Related Experiment Video
Updated: Aug 12, 2026

Simulation of Human-induced Vibrations Based on the Characterized In-field Pedestrian Behavior
Published on: April 13, 2016
Vibration, acceleration, gravitation, and movement: activity controlled rate adaptive pacing during treadmill
R Candinas1, M Jakob, T A Buckingham
1Department of Internal Medicine, University Hospital, Zürich, Switzerland.
Abstract:
Activity-based sensors for rate adaptive pacing have been available for several years and now include several different types: vibration; acceleration; gravitation; and movement. However, a systematic comparison evaluating the relative advantages and disadvantages of these various sensors has received little study. The purpose of the present study was to compare these sensor subtypes using treadmill testing and an outdoor test circuit, which simulated daily life activities and included both uphill and downhill walking. Pacemakers were strapped on the chest of healthy volunteers and connected to one channel of an ambulatory recording device, which also recorded the subject's intrinsic heart rate. The pacemakers were programmed using an initial treadmill test to standardize the rate responsive parameters for each device. Nine different pacemaker models were studied including 3 vibration-based (Elite, Synchrony, Metros), 4 acceleration-based (Relay, Excel, Ergos, Trilogy), 1 gravitational-based (Swing), and 1 movement-based (Sensorithm) device. All devices demonstrated a prompt rate response with casual walking on flat ground. The vibration-, gravitational-, and movement-based pacemakers showed a pronounced rate decline during more strenuous work, e.g., walking uphill. This phenomenon was absent in the accelerometer-based units. In particular, the vibration- and movement-based units showed a higher rate with walking downhill compared to uphill. An optimally tuned rate behavior on the treadmill usually did not provide an optimal rate behavior during daily activities and there was a tendency to overstimulation during low workload. The development of the two newest sensors (gravitational and movement) did not result in an improved performance of rate response behavior. Overall, the accelerometer-based pacemakers simulated or paralleled sinus rate behavior the most closely.
More Related Videos
08:36The Immersive Cleveland Clinic Virtual Reality Shopping Platform for the Assessment of Instrumental Activities of Daily Living
Published on: July 28, 2022
06:00A Rehabilitation Program of Exoskeleton-assisted Body Weight-Supported Treadmill Training with Non-immersive Virtual Reality for Stroke Patients
Published on: May 16, 2025
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes