Autonomic Function Following Concussion in Youth Athletes: An Exploration of Heart Rate Variability Using 24-hour Recording Methodology
Published on: September 21, 2018
Unconstrained heart-rate monitoring during bathing
T Tamura1, T Yoshimura, K Nakajima
1Tokyo Medical and Dental University, Department of Electric and Electronic Engineering, Faculty of Engineering, Yamaguchi University, Tokyo, Japan. tamura@inst.i-mde.tmd.ac.jp
Abstract:
An unconstrained electrocardiograph (ECG) and heart-rate monitor was designed to record ECG measurements in the bathtub. The apparatus consists of analog and digital parts. In the analog part, electrocardiographic signals obtained from electrodes placed inside the bathtub were amplified approximately 4,000 times. The electrodes were made of stainless steel and were 104 x 74 x 0.5 mm in size, including the absorbent sponge covers. Each electrode fitted into a plastic case 110 x 79 x 23 mm in size. Working electrodes were placed 20 cm from the bottom of the long bathtub wall, close to the position of the immersed trunk, and a reference electrode was placed 5 cm from the bottom of the side wall close to the toe position. In the digital part of the system the heart rate was calculated from the R-R interval of each ECG pulse and the calculated data were stored in a random-access memory. These stored data were transferred to a personal computer through an RS 232C interface and analyzed. The heart rates obtained from the bathtub ECG agreed with those obtained from a body-surface ECG. During measurements in bathwater with various concentrations of sodium chloride, the amplitude of the electrocardiographic waveform decreased as the electrical conductivity increased. The frequency characteristics of the bathtub ECG varied with the bathtub dimensions and the electrical conductivity of the water. Using this apparatus, heart-rate measurements can be obtained easily and noninvasively, but interpretation of the ECG signal requires great care. This monitor could be used as a home health heart-rate monitor.
More Related Videos
09:24A Rapidly Incremented Tethered-Swimming Maximal Protocol for Cardiorespiratory Assessment of Swimmers
Published on: January 28, 2020
09:50Real-World M3-BREATHE: Toward Multimodal Mobile Monitoring of Behaviour, Respiration, and Exposures for Treatment and Health Evaluation
Published on: June 5, 2026
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Holter Monitor: 24-Hour Monitoring