Expulsive iridodialysis: an isolated injury after phacoemulsification
1King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia.
Journal of Cataract and Refractive Surgery
|June 1, 1997
Abstract:
I report a case of blunt trauma to an eye that had had uneventful phacoemulsification through a 5.0 mm self-sealing corneoscleral incision 4 months earlier. Total iris expulsion occurred through the cataract incision without extension of the wound or disruption of the posterior capsule or intraocular lens. A possible mechanism for this injury is discussed and related to the unique properties of the corneoscleral incision.