False identification of urinary ephedrine as methamphetamine by gas chromatography/mass spectrometry with a DB-17
T Takayasu1, T Ohshima, M Ohtsuji
1Department of Legal Medicine, Kanazawa University Faculty of Medicine, School of Medicine, Japan.
Abstract:
A 17-year-old motorcyclist was killed in a traffic accident. The urine sample collected at autopsy was screened by the Toxi-Lab system; it showed a possible presence of either methamphetamine (MA) or ephedrine (Eph). Gas chromatography-mass spectrometry (GC-MS) was carried out for a trifluoroacetyl (TFA)-derivatized sample after extraction with an Extrelut column. A peak was detected at the same retention time as that of the authentic Eph by GC-MS with a DB-17 wide-bore column; the mass spectrum of the peak was, however, very similar to that of MA. The presence of Eph and absence of MA were proved by GC-MS using a DB-1 column. The Eph in the urine was further confirmed by high performance liquid chromatography (HPLC)-MS using an ODS column. By the REMEDi HS system, Eph and methylephedrine were determined in the urine, and their concentrations (hydrochloride salt) were 0.752 and 2.13 micrograms/ml, respectively. Ethanol was detected as well in the blood (1.55 mg/ml) and urine (2.01 mg/ml) by a pulse heating method. Nicotine, caffeine and dihydrocodeine were also qualitatively detected in the urine by Toxi-Lab, HPLC-MS and REMEDi HS systems. The present case warned that urinary Eph can be misidentified as MA by GC-MS with an intermediately polar column after TFA derivatization.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
High-Resolution Mass Spectrometry (HRMS)
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II