High-resolution density gradient electrophoresis of subcellular organelles and proteins under nondenaturing
A Tulp1, M Fernandez-Borja, D Verwoerd
1The Netherlands Cancer Institute, Amsterdam. atulp@nki.nl
Abstract:
We have developed a density gradient electrophoresis device (DGE) and used it for the preparative separation of various endocytic organelles that are hard to separate by other means. Our separation by DGE of late endosomal vesicles, recycling vesicles, early endosomes and plasma membranes is unmatched. Using the same DGE device, we performed preparative high-resolution rate zonal separation of proteins using amphoteric buffers as originally described by Bier (Electrophoresis 1993, 14, 1011-1018). Isoforms of bovine beta-lactoglobulin, human apo-transferrin, and bovine erythrocyte carbonic anhydrase that have isoelectric points within 0.8 pH units were readily separated even in the absence of nonionic detergents. The DGE apparatus is inexpensive and has unique separation abilities for vesicles and proteins.
Related Concept Videos
Subcellular Fractionation
Differential Centrifugation
Differential centrifugation is...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...