Related Experiment Video
Updated: Aug 1, 2026

Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
Importance of the sampling site for measurement of mixed venous oxygen saturation in shock
1Intensive Care Unit, University Hospital of South Manchester, UK.
Objectives:
To determine if oxyhemoglobin saturation in blood samples taken from the superior vena cava or right atrium can be substituted for oxyhemoglobin saturation in blood taken from the proximal pulmonary artery (SVO2) in patients in shock.
Design:
Prospective clinical investigation.
Setting:
Mixed surgical/medical intensive care unit in a university hospital.
Patients:
Thirty consecutive patients in severe circulatory shock who required insertion of a pulmonary artery flotation catheter (PAFC) immediately on intensive care unit admission. All patients fulfilled the criteria described below which were established in advance.
Measurements And Main Results:
Oxyhemoglobin saturation in the superior vena cava, right atrium, and pulmonary artery (SVO2) was measured by cooximetry in consecutive blood samples from each site during initial insertion of the PAFC. The mean standard deviation of values from these sites was similar: 74 +/- 12.5%, 70.+/- 13%, and 71.3 +/- 12.7%, respectively. However, when superior vena cava and right atrial oxyhemoglobin saturations and SvO2 were compared, the ranges and 95% confidence limits were found to be clinically unacceptable. The ranges were -19.3 to 23.1% and -19.7 to 16.7%, respectively, and the 95% confidence limits were -18.4 to 24.2% and -18.6 to +17.3%, respectively.
Conclusions:
These wide range differences and confidence limits would lead to large errors if superior vena cava or right atrial oxyhemoglobin saturations were substituted for true mixed venous blood in oxygen transport or pulmonary venous admixture calculations, or if clinical decision making was based on individual results. In patients in shock in whom clinical decisions may be based on the value of mixed venous oxyhemoglobin, oxyhemoglobin saturation is only reliably measured in samples taken from the pulmonary artery.
More Related Videos
07:51Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...