Related Experiment Videos
A sensitive assay of 5-fluorouracil in plasma by gas chromatography-mass spectrometry
British Journal of Clinical Pharmacology
|February 1, 1976
Abstract:
1 A gas chromatographic-mass spectrometric method was developed for determining 5-fluorouracil in plasma, using methylated thymine as an internal standard. 2 5-fluorouracil was extracted from plasma by a novel procedure which removed plasma components interferring with the sensitivity of the assay. The method included heating the plasma, washing with ether and extracting the drug under optimum conditions. 3 The sensitivity of the assay was 10 ng/ml plasma, sufficient to determine the low concentrations of 5-fluorouracil found in plasma during continuous infusion of the drug in patients receiving chemotherapy for cancer.