The mean ventricular fibrillation cycle length: a potentially useful parameter for programming implantable
1Department of Internal Medicine, University of Nebraska Medical Center, Omaha 68198-2265, USA. huaguili@unmc.edu
Abstract:
In programming the implantable cardioverter defibrillator (ICD), the ventricular tachycardia (VT) detection cycle length (CL) is based on the CL of the documented tachycardia but the ventricular fibrillation (VF) detection CL is set arbitrarily. Appropriate programming of VF detection may not only reduce the incidence of inappropriate ICD shocks for non-VF rhythms but can also avoid the fatal underdetection of VF. The mean VFCL may provide a useful parameter for optimal ICD programming for VF detection if it is reproducible. This study examined the intrapatient reproducibility and interpatient variation of the mean VFCL in 30 ICD patients (25 men and 5 women, mean age 63 +/- 13 years). A total of 210 VF episodes (7 +/- 4 per patient, range 3-17) induced by T-wave shocks (166) or AC (44) at the ICD implant (30 patients) and the predischarge test (12 of 30 patients) were analyzed. The mean VFCL was calculated from the stored V-V intervals in the ICDs. Although the mean VFCL varied significantly from 171 +/- 6 to 263 +/- 11 ms (P < 0.01) among different patients, it was reproducible among different VF episodes in an individual patient (maximal variation 4-50 ms, P > 0.05). The mean VFCL was not significantly different between patients with and without antiarrhythmic drugs (210 +/- 32 vs 210 +/- 23 ms, P > 0.05) and was correlated with the ventricular effective refractory period (r = 0.5, P < 0.05). The mean VFCL varies greatly among different patients but remains reproducible in an individual patient, suggesting that the mean VFCL may serve as a reference for ICD programming of VF detection.
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Dysrhythmias III: Characteristics of Dysrhythmias
Dysrhythmias VI: Management of Dysrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias