[2D and 3D parameter images for the analysis of contrast medium distribution in dynamic CT and MRI]
Related Experiment Video
Updated: Oct 27, 2026

High Resolution 3D Imaging of Ex-Vivo Biological Samples by Micro CT
Published on: June 21, 2011
J Beier1, T Büge, C Stroszczynski
1Strahlen- und Poliklinik, Medizinische Fakultät, Humboldt-Universität Berlin.
Aim:
For dynamic contrast medium (CM) studies, parameter images exploit specific features of the time/intensity curve (TIC) of each pixel and represent these values in a new image. Existing concepts of two-dimensional CM analysis are extended for three-dimensional applications using adequate computer graphic visualization.
Methods:
Imaging: intravenous CM injection; first-pass analysis using fast CT acquisition of a single slice; CM accumulation by 40 MR slices (6 sequences every 90 s = 240 images): Software: TIC of arbitrary 2D/3D regions; parameter images: (1) temporal maximum intensity projection (TMIP) of all voxels over time, (2) temporal CM gradients (TG) based on TIC amplitude, (3) TIC slope, (4) time of TIC peak, (5) correlation coefficient to reference TIC. The calculated 3D data of CM accumulation was visualized using multiplanar reformation, MIP, surface reconstruction, volume rendering, texture mapping and animation.
Results:
In first-pass analyses, TMIP and TG allowed the simultaneous or separated presentation of different temporal phases of the CM bolus. Correlation images emphasized regions with similarities to given TIC patterns. Three-dimensional computer graphic techniques enabled (1) anatomical/functional mapping of original image and CM accumulation and (2) fused display of both spatial CM enhancement and color-encoded time of TIC peak in one common image.
Conclusions:
The quantification of presence, magnitude, and time-of-peak of CM accumulation in local image regions supports the assessment of vascularization and of ischemic or necrotic areas.
More Related Videos
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies III: Computed Tomography

