Search research articles
Contact Us
Filters
Showing results (1-10 of 24) with videos related to
Page
of 3
Sort By:
Applied Optics
|
February 3, 2016
Three-dimensional ray-tracing model for the study of advanced refractive errors in keratoconus
Staffan Schedin, Per Hallberg, Anders Behndig
Applied Optics
|
December 15, 2017
Analysis of long-term visual quality with numerical 3D ray tracing after corneal crosslinking treatment
Staffan Schedin, Per Hallberg, Anders Behndig
Applied Optics
|
July 14, 2016
Optimization of an intraocular lens for correction of advanced corneal refractive errors
Eddie Wadbro, Per Hallberg, Staffan Schedin
Journal of Glaucoma
|
January 17, 2007
Clinical evaluation of applanation resonance tonometry: a comparison with Goldmann applanation tonometry
Per Hallberg, Anders Eklund, Tomas Bäcklund, et al.
Acta Ophthalmologica
|
December 21, 2007
Pascal, ICare and Goldmann applanation tonometry--a comparative study
Gauti Jóhannesson, Per Hallberg, Anders Eklund, et al.
Medical & Biological Engineering & Computing
|
August 26, 2006
Symmetric sensor for applanation resonance tomometry of the eye
Per Hallberg, Christina Lindén, Tomas Bäcklund, et al.
Acta Ophthalmologica
|
February 18, 2011
Introduction and clinical evaluation of servo-controlled applanation resonance tonometry
Gauti Jóhannesson, Per Hallberg, Anders Eklund, et al.
Acta Ophthalmologica
|
March 18, 2014
Initial results from mechanical compression of the cornea during crosslinking for keratoconus
Jeannette Beckman Rehnman, Anders Behndig, Per Hallberg, et al.
Investigative Ophthalmology & Visual Science
|
June 26, 2003
An applanation resonator sensor for measuring intraocular pressure using combined continuous force and area measurement
Anders Eklund, Per Hallberg, Christina Lindén, et al.
JAMA Ophthalmology
|
August 30, 2014
Increased corneal hysteresis after corneal collagen crosslinking: a study based on applanation resonance technology
Jeannette Beckman Rehnman, Anders Behndig, Per Hallberg, et al.
Page
of 3
Search research articles
Search
Showing results (1-10 of 24) with videos related to
Sort By:
Page
of 3
Applied Optics
|
February 3, 2016
Three-dimensional ray-tracing model for the study of advanced refractive errors in keratoconus
Staffan Schedin, Per Hallberg, Anders Behndig
Applied Optics
|
December 15, 2017
Analysis of long-term visual quality with numerical 3D ray tracing after corneal crosslinking treatment
Staffan Schedin, Per Hallberg, Anders Behndig
Applied Optics
|
July 14, 2016
Optimization of an intraocular lens for correction of advanced corneal refractive errors
Eddie Wadbro, Per Hallberg, Staffan Schedin
Journal of Glaucoma
|
January 17, 2007
Clinical evaluation of applanation resonance tonometry: a comparison with Goldmann applanation tonometry
Per Hallberg, Anders Eklund, Tomas Bäcklund, et al.
Acta Ophthalmologica
|
December 21, 2007
Pascal, ICare and Goldmann applanation tonometry--a comparative study
Gauti Jóhannesson, Per Hallberg, Anders Eklund, et al.
Medical & Biological Engineering & Computing
|
August 26, 2006
Symmetric sensor for applanation resonance tomometry of the eye
Per Hallberg, Christina Lindén, Tomas Bäcklund, et al.
Acta Ophthalmologica
|
February 18, 2011
Introduction and clinical evaluation of servo-controlled applanation resonance tonometry
Gauti Jóhannesson, Per Hallberg, Anders Eklund, et al.
Acta Ophthalmologica
|
March 18, 2014
Initial results from mechanical compression of the cornea during crosslinking for keratoconus
Jeannette Beckman Rehnman, Anders Behndig, Per Hallberg, et al.
Investigative Ophthalmology & Visual Science
|
June 26, 2003
An applanation resonator sensor for measuring intraocular pressure using combined continuous force and area measurement
Anders Eklund, Per Hallberg, Christina Lindén, et al.
JAMA Ophthalmology
|
August 30, 2014
Increased corneal hysteresis after corneal collagen crosslinking: a study based on applanation resonance technology
Jeannette Beckman Rehnman, Anders Behndig, Per Hallberg, et al.
Page
of 3