砂纸:通过环境质谱测量分析可抛光固体样本的高效介质
Larissa Batista Dos Santos1, Diego Magalhães Costa1, Mariana Ramos Almeida1
1Departamento de Química, Universidade Federal de Minas Gerais, Belo Horizonte, MG 31270-901, Brazil.
Journal of the American Society for Mass Spectrometry
|June 30, 2023
概括
一种新方法,砂纸喷雾质谱法 (SPS-MS),使用砂纸分析像咖啡豆这样的固体样本. 这种技术有效地识别化合物,并为硬表面提供比现有方法的优势.
科学领域:
- 分析化学 分析化学
- 材料科学 是一种材料科学.
背景情况:
- 纸喷雾质谱法 (PS-MS) 是用于分析各种样品的常见技术.
- 使用PS-MS分析固体样本可能是具有挑战性的,因为样本准备有困难.
研究的目的:
- 引入一种新的质谱技术,用于分析可抛光的固体样本.
- 为了证明砂纸作为喷雾质谱学的基材的有效性.
主要方法:
- 开发了使用砂纸作为样本介质的砂纸喷雾质谱法 (SPS-MS).
- 分析的咖啡豆 (n=100) 通过砂其表面,并应用甲醇和高电压.
- 利用正和负离子模式进行质谱分析.
主要成果:
- 成功识别了咖啡豆中的许多化合物,包括咖啡因,糖和碳酸盐.
- 在分析可抛光固体样本方面,SPS-MS被证明是有效的,与PS-MS相比显示了优势.
- 该技术简化了硬样本的分析,而不是切割组织碎片.
结论:
- SPS-MS是一种简单有效的分析可抛光固体样品的方法.
- 该技术具有多功能性,并有分析木材,塑料和作物谷物的潜在应用.
- SPS-MS为具有挑战性的样品类型的质谱分析提供了一个切实可行的替代方案.
相关概念视频
Preparation of Samples for Electron Microscopy
To be visualized by an electron microscope, either transmission or scanning, biological samples need to be fixed (stabilized) so the electron beam does not destroy them and dried thoroughly (desiccated/dehydrated) so the vacuum does not affect them. Fixation needs to be done as quickly as possible because the sample properties will start changing as soon as it is removed from its natural environment. For example, in a tissue sample, the oxygen levels begin decreasing, causing an altered...
Sample Preparation for Analysis: Advanced Techniques
Accurate analysis of complex samples often requires advanced preparation techniques to achieve reliable and reproducible results. Samples containing inorganic or organic materials can be challenging to dissolve or decompose effectively. Standard sample preparation methods include acid digestion, fusion, dry ashing, and wet digestion.
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Atomic Absorption Spectroscopy: Lab
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...