一个积极的振动隔离和补偿系统,以提高光学图像质量:建模和实验
Min Wang1,2, Jing Xiong1, Shibo Fu1
1School of Mechatronic Engineering and Automation, Shanghai University, Shanghai 200444, China.
Micromachines
|July 29, 2023
概括
这项研究开发了一种活性振动隔离和补偿系统 (VICS),以提高光学成像质量. 维克斯显著减少振动影响,改善图像性能指标.
科学领域:
- 光学工程是指光学工程.
- 控制系统工程 控制系统工程
背景情况:
- 光学检测设备 (ODE) 中的振动会降低成像质量.
- 有效的振动隔离对于高准确度的光学测量至关重要.
研究的目的:
- 为ODE开发和评估一个活跃的振动隔离和补偿系统 (VICS).
- 通过减轻振动效应来提高光学成像质量.
主要方法:
- 为摄像机设计了一个活跃的振动隔离器.
- 采用双循环控制策略,具有位置补偿和整体力反 (IFF).
- 建立了振动和图像质量之间的映射;提出了一种性能指标.
主要成果:
- 在自然频率下,达到13.95dB的峰值振动降低.
- 与没有VICS的系统相比,将隔离带宽扩大了11.76Hz.
- 在接近自然频率的图像性能指标值中显示了46.03%的增加.
结论:
- 开发的VICS有效隔离振动,显著提高光学成像质量.
- 拟议的系统为提高光学检测设备在振动环境中的性能提供了一种实际解决方案.
相关概念视频
Control Systems
1.2K
Control systems are everywhere in contemporary society, influencing diverse applications from aerospace to automated manufacturing. These systems can be found naturally within biological processes, such as blood sugar regulation and heart rate adjustment in response to stress, as well as in man-made systems like elevators and automated vehicles. A control system is essentially a network of subsystems and processes that collaboratively convert specific inputs into desired outputs.
At the heart...
At the heart...
1.2K
Phase Contrast and Differential Interference Contrast Microscopy
8.2K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
8.2K