相关实验视频
Updated: Jun 21, 2025

04:43
Visualizing Visual Adaptation
Published on: April 24, 2017
8.9K
适应性全球效应:亮度对比度调节全球效应区域
Jessica Heeman1, Jan Theeuwes2, Stefan Van der Stigchel3
1Faculty of Social and Behavioral Sciences, Experimental Psychology, Helmholtz Institute, Utrecht University, Utrecht, The Netherlands; Faculty of Behavioral and Movement Sciences, Department of Cognitive Psychology, Vrije Universiteit, Amsterdam, The Netherlands.
Vision research
|July 10, 2024
概括
当一个分心器比目标亮得多时,萨卡德平均区会扩大,这表明它的自适应性. 这一区域也随着更高的亮度和更短的顺序响应时间而增加.
科学领域:
- 神经科学是一个神经科学.
- 视觉科学科学 视觉科学
- 眼运动研究 眼运动研究
背景情况:
- 当物体靠近时,斜视眼动表现出"全局效应"或"斜视平均值".
- 这种平均化现象随着物体分离的增加而减少.
- 萨卡德平均区对物体特征的适应性仍然在很大程度上未被探索.
研究的目的:
- 为了研究,如果saccade平均区适应物体亮度对比度的变化.
- 为了确定相对和绝对亮度对平均区域大小的影响.
主要方法:
- 进行了两项涉及斜视眼动的实验.
- 记录了观察者的动,而目标和分心器的亮度有所变化.
- 在不同的亮度条件下,系统评估了萨卡德平均区的大小.
主要成果:
- 当分心器相对于目标具有较高的亮度时,观察到更大的平均区域.
- 即使使用远程分心器,萨卡德平均值也持续存在.
- 同等发光的目标和分心器在绝对发光率的平均区域没有变化.
- 增加的相对和绝对亮度扩大了平均区,特别是在更短的顺序响应时间.
结论:
- 萨卡德平均区适应于亮度对比度.
- 平均区的尺寸随着相对亮度的提高和相应反应时间的缩短而增加.
- 亮度对比在调节眼运动平均行为方面发挥着至关重要的作用.
相关概念视频
Phase Contrast and Differential Interference Contrast Microscopy
7.7K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
7.7K
Confocal Fluorescence Microscopy
13.2K
Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
13.2K
Properties of the z-Transform I
181
The z-transform is a fundamental tool in digital signal processing, enabling the analysis of discrete-time systems through its various properties. It is an invaluable tool for analyzing discrete-time systems, offering a range of properties that simplify complex signal manipulations. One fundamental property is linearity. For any two discrete-time signals, the z-transform of their linear combination equals the same linear combination of their individual z-transforms. This property is essential...
181
MOSFET: Enhancement Mode
320
Enhancement-mode MOSFETs are pivotal components in electronics, distinguished by their capacity to act as highly efficient switches. They are part of the larger family of metal-oxide Semiconductor Field-Effect Transistors (MOSFETs). They are available in two types: p-channel and n-channel, each tailored to specific polarity operations.
In their basic form, enhancement-mode MOSFETs are typically non-conductive when the gate-source voltage (Vgs) is zero. This default 'off' state means no...
In their basic form, enhancement-mode MOSFETs are typically non-conductive when the gate-source voltage (Vgs) is zero. This default 'off' state means no...
320

